ALXD800EEXJCVD C3 AMD (ADVANCED MICRO DEVICES), ALXD800EEXJCVD C3 Datasheet - Page 453

no-image

ALXD800EEXJCVD C3

Manufacturer Part Number
ALXD800EEXJCVD C3
Description
Manufacturer
AMD (ADVANCED MICRO DEVICES)
Datasheet

Specifications of ALXD800EEXJCVD C3

Operating Temperature (min)
0C
Operating Temperature (max)
85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Lead Free Status / RoHS Status
Compliant
Video Processor Register Descriptions
6.8.3.44 Panel Timing Register 2 (PT2)
VP Memory Offset 408h
Type
Reset Value
AMD Geode™ LX Processors Data Book
63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
63:32
26:24
21:20
Bit
31
30
29
28
27
23
22
Name
RSVD (RO)
SP
TFT_PASS_
THRU
LPOL
RSVD
SCRC
RSVD
VSP
HSP
RSVD
R/W
00000000_00000000h
RSVD
Description
Reserved (Read Only). Reads back as 0.
Spare. Bit is read/write, but has no function.
TFT Pass Through. Activates the TFT Pass Through mode. In TFT Pass Through
mode, the input timing and the pixel data is passed directly on to the panel interface tim-
ing and the panel data pins to drive the TFT panel. In Pass Through mode the internal FP
TFT logic and timing is not used.
0: Normal mode; uses the TFT logic and timing from the FP.
1: TFT Pass Through mode; FP TFT timing logic functions are not used.
Display Timing Strobe Polarity Select. Selects the polarity of the LDE/MOD pin. This
can be used for panels that require an active low timing LDE interface signal.
0: LDE/MOD signal is active high. (Default)
1: LDE/MOD signal is active low
Reserved. This bit is not defined.
Panel Shift Clock Retrace Activity Control. Programs the shift clock (SHFCLK) to be
either free running, or active only during the display period. Some TFT panels recom-
mend keeping the shift clock running during the retrace time.
0: Shift clock is active only during active display period.
1: Shift clock is free running during the entire frame period.
Reserved. These bits are not defined.
Vertical Sync Output Polarity. Selects polarity of the output VSYNC signal. Note that
VP Memory Offset 400h[30] selects the polarity of the input VSYNC.
0: VSYNC output is active high.
1: VSYNC output is active low
Horizontal Sync Output Polarity. Selects polarity of output HSYNC signal. Note that
VP Memory Offset 400h[29] selects the polarity of the input HSYNC, and this bit controls
the output polarity.
0: HSYNC output is active high.
1: HSYNC output is active low
Reserved. These bits are not defined.
RSVD
PT2 Bit Descriptions
PT2 Register Map
PIXF
RSVD
9
RSVD
8
33234H
7
6
5
4
3
2
1
453
0

Related parts for ALXD800EEXJCVD C3