EP4SGX290KF40C3N Altera, EP4SGX290KF40C3N Datasheet - Page 63

IC STRATIX IV GX 290K 1517FBGA

EP4SGX290KF40C3N

Manufacturer Part Number
EP4SGX290KF40C3N
Description
IC STRATIX IV GX 290K 1517FBGA
Manufacturer
Altera
Series
Stratix® IV GXr

Specifications of EP4SGX290KF40C3N

Number Of Logic Elements/cells
291200
Number Of Labs/clbs
11648
Total Ram Bits
17248
Number Of I /o
744
Voltage - Supply
0.87 V ~ 0.93 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
1517-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Other names
544-2624

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4SGX290KF40C3N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4SGX290KF40C3N
Manufacturer:
ALTERA
0
Part Number:
EP4SGX290KF40C3NB
Manufacturer:
ALTERA
0
Chapter 3: TriMatrix Embedded Memory Blocks in Stratix IV Devices
Overview
February 2011 Altera Corporation
Error Correction Code (ECC) Support
1
1
Stratix IV M144K blocks have built-in support for error correction code (ECC) when in
×64-wide simple dual-port mode. ECC allows you to detect and correct data errors in
the memory array. The M144K blocks have a single-error-correction
double-error-detection (SECDED) implementation. SECDED can detect and fix a
single bit error in a 64-bit word, or detect two bit errors in a 64-bit word. It cannot
detect three or more errors.
The M144K ECC status is communicated using a three-bit status flag
eccstatus[2..0]. The status flag can be either registered or unregistered. When
registered, it uses the same clock and asynchronous clear signals as the output
registers. When unregistered, it cannot be asynchronously cleared.
Table 3–3
Table 3–3. Truth Table for ECC Status Flags
You cannot use the byte enable feature when ECC is engaged.
Read-during-write “old data mode” is not supported when ECC is engaged.
No error
Single error and fixed
Double error and no fix
Illegal
Illegal
Illegal
Illegal
lists the truth table for the ECC status flags.
Status
eccstatus[2]
0
0
1
0
0
1
1
eccstatus[1]
0
1
0
0
1
0
1
Stratix IV Device Handbook Volume 1
eccstatus[0]
0
1
1
1
0
0
X
3–7