GS4910B GENNUM [Gennum Corporation], GS4910B Datasheet - Page 46

no-image

GS4910B

Manufacturer Part Number
GS4910B
Description
HD/SD/Graphics Clock and Timing Generator with GENLOCK
Manufacturer
GENNUM [Gennum Corporation]
Datasheet
3.5.2.1 Ambiguous Standard Selection
If the input signal is valid, the device then compares the timing parameters of the
input reference signal to each of the 36 video and 16 graphics standards listed in
Table
standards. If it is, the VID_STD[5:0] value for the format is written to the
Input_Standard register at address 0Fh of the host interface. If the input signal is
invalid, or if the reference format is unrecognized, 00h is programmed in this
register.
Once a reference signal is valid and recognized by the device, VSYNC and FSYNC
will no longer be monitored. Loss of signal on these pins will not affect the operation
of the device.
If VID_STD[5:0] is not set to 62 and the REF_LOST pin is HIGH, or if the input
signal is valid, but unrecognized as one of the 36 video or 16 graphics formats, the
GENLOCK pin should not be set LOW.
If VID_STD[5:0] = 62, the REF_LOST output will reflect the presence of a stable
signal with a period of less than 2.4ms on the HSYNC input pin. This allows the
user to program the device to lock to a single input reference only
The REF_LOST output pin may also be read via bit 0 of the Genlock_Status
register (see
There are some standards with identical H, V, and F timing parameters, such that
the GS4911B/GS4910B’s reference format detector cannot distinguish between
them.
Amb_Std_Sel register at address 10h of the host interface, the user may select
their choice of standard to be identified with a particular set of measurements. For
example, to have 1716 clocks of 27MHz per line with 525 lines per frame identified
as 4fsc 525, program Amb_Std_Sel[10:0] = XXX10XXXXXX, where ‘X’ signifies
‘don’t care’.
36655 - 2
1-2, and determines if the input reference is one of the recognized
Table 3-2
April 2006
Section 3.12.3 on page
groups standards with shared H, V, and F periods. Using the
79).
GS4911B/GS4910B Data Sheet
46 of 113

Related parts for GS4910B