AT91SAM9263B-CU Atmel, AT91SAM9263B-CU Datasheet - Page 795

IC ARM9 MCU 200 MHZ 324-TFBGA

AT91SAM9263B-CU

Manufacturer Part Number
AT91SAM9263B-CU
Description
IC ARM9 MCU 200 MHZ 324-TFBGA
Manufacturer
Atmel
Series
AT91SAMr
Datasheets

Specifications of AT91SAM9263B-CU

Core Processor
ARM9
Core Size
16/32-Bit
Speed
240MHz
Connectivity
CAN, Ethernet, I²C, MMC, SPI, SSC, UART/USART, USB
Peripherals
AC'97, LCD, POR, PWM, WDT
Number Of I /o
160
Program Memory Size
128KB (128K x 8)
Program Memory Type
ROM
Ram Size
128K x 8
Voltage - Supply (vcc/vdd)
1.08 V ~ 1.32 V
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
324-TFBGA
Processor Series
AT91SAMx
Core
ARM926EJ-S
Data Bus Width
32 bit
Data Ram Size
96 KB
Interface Type
2-Wire, EBI, I2S, MCI, SPI, USART
Maximum Clock Frequency
200 MHz
Number Of Programmable I/os
160
Number Of Timers
4
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
JTRACE-ARM-2M, MDK-ARM, RL-ARM, ULINK2
Development Tools By Supplier
AT91SAM-ICE, AT91-ISP, AT91SAM9263-EK
Minimum Operating Temperature
- 40 C
Package
324TFBGA
Device Core
ARM926EJ-S
Family Name
91S
Maximum Speed
200 MHz
Operating Supply Voltage
1.8|2.5|3.3 V
Controller Family/series
AT91SAM9xxx
No. Of I/o's
160
Ram Memory Size
96KB
Cpu Speed
240MHz
No. Of Timers
1
Rohs Compliant
Yes
For Use With
AT91SAM9263-EK - KIT EVAL FOR AT91SAM9263AT91SAM-ICE - EMULATOR FOR AT91 ARM7/ARM9
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Data Converters
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Q3735625

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM9263B-CU
Manufacturer:
IDT
Quantity:
1 043
Part Number:
AT91SAM9263B-CU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM9263B-CU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT91SAM9263B-CU-100
Manufacturer:
ATMEL
Quantity:
1 000
Part Number:
AT91SAM9263B-CU-100
Manufacturer:
ATMEL
Quantity:
3 060
Part Number:
AT91SAM9263B-CU-100
Manufacturer:
Atmel
Quantity:
10 000
line (DAT0) to LOW. The card stops pulling down the data line as soon as at least one receive buffer for the defined data
transfer block length becomes free.
The NOTBUSY flag allows to deal with these different states.
0 = The MCI is not ready for new data transfer. Cleared at the end of the card response.
1 = The MCI is ready for new data transfer. Set when the busy state on the data line has ended. This corresponds to a free
internal data receive buffer of the card.
Refer to the MMC or SD Specification for more details concerning the busy behavior.
• ENDRX: End of RX Buffer
0 = The Receive Counter Register has not reached 0 since the last write in MCI_RCR or MCI_RNCR.
1 = The Receive Counter Register has reached 0 since the last write in MCI_RCR or MCI_RNCR.
• ENDTX: End of TX Buffer
0 = The Transmit Counter Register has not reached 0 since the last write in MCI_TCR or MCI_TNCR.
1 = The Transmit Counter Register has reached 0 since the last write in MCI_TCR or MCI_TNCR.
Note:
• RXBUFF: RX Buffer Full
0 = MCI_RCR or MCI_RNCR has a value other than 0.
1 = Both MCI_RCR and MCI_RNCR have a value of 0.
• TXBUFE: TX Buffer Empty
0 = MCI_TCR or MCI_TNCR has a value other than 0.
1 = Both MCI_TCR and MCI_TNCR have a value of 0.
Note:
• RINDE: Response Index Error
0 = No error.
1 = A mismatch is detected between the command index sent and the response index received. Cleared when writing in
the MCI_CMDR.
• RDIRE: Response Direction Error
0 = No error.
1 = The direction bit from card to host in the response has not been detected.
• RCRCE: Response CRC Error
0 = No error.
1 = A CRC7 error has been detected in the response. Cleared when writing in the MCI_CMDR.
• RENDE: Response End Bit Error
0 = No error.
1 = The end bit of the response has not been detected. Cleared when writing in the MCI_CMDR.
6249H–ATARM–27-Jul-09
BLKE and NOTBUSY flags can be used to check that the data has been successfully transmitted on the data lines and not only
transferred from the PDC to the MCI Controller.
BLKE and NOTBUSY flags can be used to check that the data has been successfully transmitted on the data lines and not only
transferred from the PDC to the MCI Controller.
AT91SAM9263
795