HD64F36912GFH Renesas Electronics America, HD64F36912GFH Datasheet - Page 254

IC H8 MCU FLASH 8K 32-QFP

HD64F36912GFH

Manufacturer Part Number
HD64F36912GFH
Description
IC H8 MCU FLASH 8K 32-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300H Tinyr
Datasheet

Specifications of HD64F36912GFH

Core Processor
H8/300H
Core Size
16-Bit
Speed
12MHz
Connectivity
I²C, SCI
Peripherals
LVD, POR, PWM, WDT
Number Of I /o
18
Program Memory Size
8KB (8K x 8)
Program Memory Type
FLASH
Ram Size
1.5K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 4x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
32-LQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F36912GFH
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 14 Serial Communication Interface 3 (SCI3)
Reception cannot be resumed while a receive error flag is set to 1. Accordingly, clear the OER,
FER, PER, and RDRF bits to 0 before resuming reception. Figure 14.14 shows a sample flow
chart for serial data reception.
Rev. 3.00 Sep. 14, 2006 Page 224 of 408
REJ09B0105-0300
[4]
Figure 14.14 Sample Serial Reception Flowchart (Clocked Synchronous Mode)
Yes
No
Read receive data in RDR
Clear OER flag in SSR to 0
Clear RE bit in SCR3 to 0
Read RDRF flag in SSR
Overrun error processing
Read OER flag in SSR
All data received?
Error processing
Start reception
RDRF = 1
OER = 1
<End>
<End>
Yes
No
No
(Continued below)
Error processing
Yes
[1]
[2]
[3]
[4]
[1]
[2]
[3]
[4]
Read the OER flag in SSR to determine if
there is an error. If an overrun error has
occurred, execute overrun error processing.
Read SSR and check that the RDRF flag is
set to 1, then read the receive data in RDR.
When data is read from RDR, the RDRF
flag is automatically cleared to 0.
To continue serial reception, before the
MSB (bit 7) of the current frame is received,
reading the RDRF flag and reading RDR
should be finished. When data is read from
RDR, the RDRF flag is automatically
cleared to 0.
If an overrun error occurs, read the OER
flag in SSR, and after performing the
appropriate error processing, clear the OER
flag to 0. Reception cannot be resumed if
the OER flag is set to 1.