DS21Q55 Maxim Integrated Products, DS21Q55 Datasheet - Page 114

IC TXRX QUAD T1/E1/J1 SCT 256BGA

DS21Q55

Manufacturer Part Number
DS21Q55
Description
IC TXRX QUAD T1/E1/J1 SCT 256BGA
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS21Q55

Function
Transceiver
Interface
E1, J1, T1
Number Of Circuits
4
Voltage - Supply
3.14 V ~ 3.47 V
Current - Supply
75mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
256-BGA
Includes
BERT Generator and Detector, Dual HDLC Controllers
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Power (watts)
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS21Q55
Manufacturer:
DS
Quantity:
959
Part Number:
DS21Q55
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS21Q552
Manufacturer:
DS
Quantity:
7
Part Number:
DS21Q552
Manufacturer:
DALLAS
Quantity:
319
Part Number:
DS21Q552
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS21Q552+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS21Q552BN+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS21Q552N+
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
DS21Q554
Manufacturer:
DS
Quantity:
20
Part Number:
DS21Q554
Manufacturer:
AD
Quantity:
301
Part Number:
DS21Q554
Manufacturer:
DALLAS
Quantity:
20 000
Part Number:
DS21Q554B+
Manufacturer:
MAXIM/美信
Quantity:
20 000
DS21Q55 Quad T1/E1/J1 Transceiver
19.
T1 BIT-ORIENTED CODE (BOC) CONTROLLER
The DS21Q55 contains a BOC generator on the transmit side and a BOC detector on the receive side. The
BOC function is available only in T1 mode.
19.1 Transmit BOC
Bits 0 to 5 in the TFDL register contain the BOC message to be transmitted. Setting BOCC.0 = 1 causes
the transmit BOC controller to immediately begin inserting the BOC sequence into the FDL bit position.
The transmit BOC controller automatically provides the abort sequence. BOC messages are transmitted as
long as BOCC.0 is set.
19.1.1 Example: Transmit a BOC
1) Write 6-bit code into the TFDL register.
2) Set the SBOC bit in BOCC = 1.
19.2 Receive BOC
The receive BOC function is enabled by setting BOCC.4 = 1. The RFDL register now operates as the
receive BOC message and information register. The lower six bits of the RFDL register (BOC message
bits) are preset to all 1s. When the BOC bits change state, the BOC change-of-state indicator, SR8.0,
alerts the host. The host then reads the RFDL register to get the BOC status and message. A change-of-
state occurs when either a new BOC code has been present for a time determined by the receive BOC
filter bits RBF0 and RBF1 in the BOCC register, or a nonvalid code is being received.
19.2.1 Example: Receive a BOC
1) Set integration time through BOCC.1 and BOCC.2.
2) Enable the receive BOC function (BOCC.4 = 1).
3) Enable interrupt (IMR8.0 = 1).
4) Wait for interrupt to occur.
5) Read the RFDL register.
6) If SR2.7 = 1, then a valid BOC message was received.
– The lower six bits of the RFDL register comprise the message.