T8207-BAL-DT Agere Systems, Inc., T8207-BAL-DT Datasheet - Page 126

no-image

T8207-BAL-DT

Manufacturer Part Number
T8207-BAL-DT
Description
CelXpres ATM interconnect. Dry-bagget, tape & reel .
Manufacturer
Agere Systems, Inc.
Datasheet
CelXpres T8207
ATM Interconnect
14 Registers
14.3.2.3 RX UTOPIA Monitoring
Table 102. PHY Port X Receive Count Structure (PPXRXCNT) (0700h to 07F8h)
126
The letter X in the data structure name and in the bit names represents the values 0 through 31 for the 32 PHY
ports. The base addresses of the 32 data structures are shown below.
in_cnt_phyX[31:16]
in_cnt_phyX[15:0]
PHY port 10 receive count 0
PHY port 11 receive count 0
PHY port 12 receive count 0
PHY port 13 receive count 0
PHY port 14 receive count 0
PHY port 15 receive count 0
PHY port 0 receive count 0
PHY port 1 receive count 0
PHY port 2 receive count 0
PHY port 3 receive count 0
PHY port 4 receive count 0
PHY port 5 receive count 0
PHY port 6 receive count 0
PHY port 7 receive count 0
PHY port 8 receive count 0
PHY port 9 receive count 0
Name
Structure Name
(continued)
Offset
00h
02h
Bit Pos.
15:0
15:0
Base Address
Type
RW
0700h
0708h
0710h
0718h
0720h
0728h
0730h
0738h
0740h
0748h
0750h
0758h
0760h
0768h
0770h
0778h
Reset
X
Incoming Cell Count for PHY Port X [31:16]. The
in_cnt_phyX[31:16] and in_cnt_phyX[15:0] fields
together are a free-running counter of cells from PHY
port X. Both valid and misrouted cells are counted.
Incoming cells are not counted if they encounter an
Ignore (I) bit in their translation records that is ‘1’ or if
their VPI and/or VCI are out of range.
Incoming Cell Count for PHY Port X [15:0]. The
in_cnt_phyX[31:16] and in_cnt_phyX[15:0] fields
together are a free-running counter of cells from PHY
port X. Both valid and misrouted cells are counted.
Incoming cells are not counted if they encounter an
Ignore (I) bit in their translation records that is ‘1’ or if
their VPI and/or VCI are out of range.
PHY port 16 receive count 0
PHY port 17 receive count 0
PHY port 18 receive count 0
PHY port 19 receive count 0
PHY port 20 receive count 0
PHY port 21 receive count 0
PHY port 22 receive count 0
PHY port 23 receive count 0
PHY port 24 receive count 0
PHY port 25 receive count 0
PHY port 26 receive count 0
PHY port 27 receive count 0
PHY port 28 receive count 0
PHY port 29 receive count 0
PHY port 30 receive count 0
PHY port 31 receive count 0