AT86RF212-ZU Atmel, AT86RF212-ZU Datasheet - Page 37

IC TXRX ZIGBE/802.15.4/ISM 32QFN

AT86RF212-ZU

Manufacturer Part Number
AT86RF212-ZU
Description
IC TXRX ZIGBE/802.15.4/ISM 32QFN
Manufacturer
Atmel
Datasheet

Specifications of AT86RF212-ZU

Frequency
700MHz, 800MHz, 900MHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4 Zigbee, 6LoWPAN, ISM
Applications
ISM, ZigBee™
Power - Output
10dBm
Sensitivity
-110dBm
Voltage - Supply
1.8 V ~ 3.6 V
Current - Receiving
9.2mA
Current - Transmitting
25mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Operating Temperature
-40°C ~ 85°C
Package / Case
32-VQFN Exposed Pad, 32-HVQFN, 32-SQFN, 32-DHVQFN
Number Of Receivers
1
Number Of Transmitters
1
Wireless Frequency
769 MHz to 935 MHz
Interface Type
SPI
Noise Figure
7 dB
Output Power
21 dB
Operating Supply Voltage
1.8 V, 3 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Maximum Supply Current
25 mA
Minimum Operating Temperature
- 40 C
Modulation
OQPSK
Protocol Supported
802.15.4
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Operating Temperature Classification
Industrial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT86RF212-ZU
Manufacturer:
HITTITE
Quantity:
5 000
Part Number:
AT86RF212-ZU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT86RF212-ZUR
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
5.1.4.4 State Change from PLL_ON via BUSY_TX to RX_ON States
8168C-MCU Wireless-02/10
Figure 5-5. Transition from TRX_OFF to PLL_ON/RX_ON State and further to
RX_ON/PLL_ON
In TRX_OFF state, entering the commands PLL_ON or RX_ON initiates a ramp-up
sequence of the internal 1.8 V voltage regulator for the analog domain (AVREG).
RX_ON state can be entered any time from PLL_ON state, regardless whether the PLL
has already locked, which is indicated by IRQ_0 (PLL_LOCK). Likewise, PLL_ON state
can be entered any time from RX_ON state.
When TRX_OFF_AVDD_EN (register 0x0C, TRX_CTRL_2) is already set in TRX_OFF
state, the analog voltage regulator is turned on immediately and the ramp up sequence
to PLL_ON or RX_ON can be accelerated.
The transition from PLL_ON to BUSY_TX state and subsequently to RX_ON state is
shown in Figure 5-6.
Figure 5-6. PLL_ON to BUSY_TX to RX_ON Timing for O-QPSK 250 kbit/s Mode
Starting from PLL_ON, it is further assumed that the PLL has already been locked. A
transmission is initiated either by a rising edge of pin 11 (SLP_TR) or by command
TX_START. The PLL settles to the transmit frequency and the PA is enabled. After the
duration of t
transmitting the internally generated SHR and the PSDU data of the Frame Buffer. After
completing the frame transmission, indicated by IRQ_3 (TRX_END), the PLL settles
back to the receive frequency within t
If during BUSY_TX the radio transmitter is requested to change to a receive state, it
automatically proceeds to state RX_ON upon completion of the transmission.
Note:
If TRX_CMD = RX_ON in TRX_OFF state, RX_ON state is entered immediately,
even if the PLL has not settled.
TR10
(1 symbol period), the AT86RF212 changes into BUSY_TX state,
TR11
and returns to state PLL_ON.