CY8CTST200-24LQXI Cypress Semiconductor Corp, CY8CTST200-24LQXI Datasheet - Page 17

no-image

CY8CTST200-24LQXI

Manufacturer Part Number
CY8CTST200-24LQXI
Description
IC MCU 32K FLASH 24UQFN
Manufacturer
Cypress Semiconductor Corp
Series
TrueTouch™r
Datasheet

Specifications of CY8CTST200-24LQXI

Program Memory Type
FLASH (32 kB)
Package / Case
24-WQFN Exposed Pad, 24-HWQFN
Applications
Touchscreen Controller
Core Processor
M8C
Controller Series
CY8CT
Ram Size
2K x 8
Interface
I²C, SPI, UART/USART, USB
Number Of I /o
20
Voltage - Supply
1.8 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Processor Series
CY8CTxx2xx
Core
M8C
Data Bus Width
8 bit
Data Ram Size
2 KB
Interface Type
I2C, SPI
Maximum Clock Frequency
24 MHz
Number Of Timers
3
Operating Supply Voltage
1.71 V to 5.5 V
Mounting Style
SMD/SMT
Program Memory Size
32 KB
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
770-1000 - ISP 4PORT FOR CYPRESS PSOC MCU
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
428-2956

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CY8CTST200-24LQXI
Manufacturer:
CY
Quantity:
487
Documentation Conventions
There are only four distinguishing font types used in this
manual, besides those found in the headings.
Register Conventions
The following table lists the register conventions that are
specific to this manual. A more detailed set of register con-
ventions is located in the
page
Register Conventions
PSoC CY8CTMG20x and CY8CTST200 TRM, Document No. 001-53603 Rev. *C
‘x’ in a register
name
R
W
O
L
C
00
XX
0,
1,
x,
Empty, grayed-
out table cell
Convention
The first is the use of italics when referencing a docu-
ment title or file name.
The second is the use of bold italics when referencing a
term described in the Glossary of this manual.
The third is the use of Times New Roman font, distinguish-
ing equation examples.
The fourth is the use of Courier New font, distinguish-
ing code examples.
187.
PRTxIE
R : 00
W : 00
RO : 00
RL : 00
RC : 00
RW : 00
RW : XX
0,04h
1,23h
x,F7h
Example
Multiple instances/address ranges of the
same register
Read register or bit(s)
Write register or bit(s)
Only a read/write register or bit(s).
Logical register or bit(s)
Clearable register or bit(s)
Reset value is 0x00 or 00h
Register is not reset
Register is in bank 0
Register is in bank 1
Register exists in register bank 0 and reg-
ister bank 1
Reserved bit or group of bits, unless oth-
erwise stated
Register Reference chapter on
Description
Numeric Naming
Hexadecimal numbers are represented with all letters in
uppercase with an appended lowercase ‘h’ (for example,
‘14h’ or ‘3Ah’) and hexadecimal numbers may also be rep-
resented by a ‘0x’ prefix, the C coding convention. Binary
numbers have an appended lowercase ‘b’ (for example,
01010100b’ or ‘01000011b’). Numbers not indicated by an
‘h’ or ‘b’ are decimal.
Units of Measure
This table lists the units of measure used in this manual.
Units of Measure
Symbol
μVrms
MHz
ppm
Kbit
kHz
mA
mV
sps
dB
Hz
KB
μA
μV
ms
nA
nV
°C
μF
μs
ns
pF
pp
fF
K
Ω
V
k
σ
degree Celsius
decibels
femtofarad
hertz
kilo, 1000
2
1024 bytes
1024 bits
kilohertz (32.000)
kilohm
megahertz
megaohm
microampere
microfarad
microsecond
microvolt
microvolts root-mean-square
milliampere
millisecond
millivolt
nanoamphere
nanosecond
nanovolt
ohm
picofarad
peak-to-peak
parts per million
samples per second
sigma: one standard deviation
volt
10
, 1024
Unit of Measure
Section A: Overview
[+] Feedback
17

Related parts for CY8CTST200-24LQXI