Specifications of C8051F320DK

Contents
Evaluation Board, Power Supply, USB Cables, Adapter and Documentation
Processor To Be Evaluated
C8051F320/F321
Interface Type
USB
Silicon Manufacturer
Silicon Labs
Core Architecture
8051
Silicon Core Number
C8051F320
Silicon Family Name
C8051F32x
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With/related Products
Silicon Laboratories C8051F320, C8051F321
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1260

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C8051F320DK
Manufacturer:
SiliconL
Quantity:
4
Bit7:
Bit6:
Bit5:
Bit4:
Bit3:
Bit2:
Bit1:
Bit0:
MASTER TXMODE
Bit7
R
MASTER: SMBus Master/Slave Indicator.
This read-only bit indicates when the SMBus is operating as a master.
0: SMBus operating in Slave Mode.
1: SMBus operating in Master Mode.
TXMODE: SMBus Transmit Mode Indicator.
This read-only bit indicates when the SMBus is operating as a transmitter.
0: SMBus in Receiver Mode.
1: SMBus in Transmitter Mode.
STA: SMBus Start Flag.
Write:
0: No Start generated.
1: When operating as a master, a START condition is transmitted if the bus is free (If the bus
is not free, the START is transmitted after a STOP is received or a timeout is detected). If
STA is set by software as an active Master, a repeated START will be generated after the
next ACK cycle.
Read:
0: No Start or repeated Start detected.
1: Start or repeated Start detected.
STO: SMBus Stop Flag.
Write:
0: No STOP condition is transmitted.
1: Setting STO to logic 1 causes a STOP condition to be transmitted after the next ACK
cycle. When the STOP condition is generated, hardware clears STO to logic 0. If both STA
and STO are set, a STOP condition is transmitted followed by a START condition.
Read:
0: No Stop condition detected.
1: Stop condition detected (if in Slave Mode) or pending (if in Master Mode).
ACKRQ: SMBus Acknowledge Request
This read-only bit is set to logic 1 when the SMBus has received a byte and needs the ACK
bit to be written with the correct ACK response value.
ARBLOST: SMBus Arbitration Lost Indicator.
This read-only bit is set to logic 1 when the SMBus loses arbitration while operating as a
transmitter. A lost arbitration while a slave indicates a bus error condition.
ACK: SMBus Acknowledge Flag.
This bit defines the out-going ACK level and records incoming ACK levels. It should be writ-
ten each time a byte is received (when ACKRQ=1), or read after each byte is transmitted.
0: A "not acknowledge" has been received (if in Transmitter Mode) OR will be transmitted (if
in Receiver Mode).
1: An "acknowledge" has been received (if in Transmitter Mode) OR will be transmitted (if in
Receiver Mode).
SI: SMBus Interrupt Flag.
This bit is set by hardware under the conditions listed in Table 16.3. SI must be cleared by
software. While SI is set, SCL is held low and the SMBus is stalled.
Bit6
R
SFR Definition 16.2.
STA
R/W
Bit5
STO
R/W
Bit4
ACKRQ ARBLOST
Rev. 1.4
Bit3
SMB0CN: SMBus Control
R
Bit2
R
ACK
R/W
Bit1
C8051F320/1
SFR Address:
R/W
Bit0
SI
0xC0
Bit Addressable
00000000
Reset Value
177