SI1000-C-GM Silicon Laboratories Inc, SI1000-C-GM Datasheet - Page 192

IC TXRX MCU + EZRADIOPRO

SI1000-C-GM

Manufacturer Part Number
SI1000-C-GM
Description
IC TXRX MCU + EZRADIOPRO
Manufacturer
Silicon Laboratories Inc
Datasheets

Specifications of SI1000-C-GM

Package / Case
42-QFN
Frequency
240MHz ~ 960MHz
Data Rate - Maximum
256kbps
Modulation Or Protocol
FSK, GFSK, OOK
Applications
General Purpose
Power - Output
20dBm
Sensitivity
-121dBm
Voltage - Supply
1.8 V ~ 3.6 V
Current - Receiving
18.5mA
Current - Transmitting
85mA
Data Interface
PCB, Surface Mount
Memory Size
64kB Flash, 4kB RAM
Antenna Connector
PCB, Surface Mount
Number Of Receivers
1
Number Of Transmitters
1
Wireless Frequency
240 MHz to 960 MHz
Interface Type
UART, SMBus, SPI, PCA
Output Power
20 dBm
Operating Supply Voltage
0.9 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Maximum Supply Current
4.1 mA
Minimum Operating Temperature
- 40 C
Modulation
FSK, GFSK, OOK
Protocol Supported
C2, SMBus
Core
8051
Program Memory Type
Flash
Program Memory Size
64 KB
Data Ram Size
4352 B
Supply Current (max)
4.1 mA
Cpu Family
Si100x
Device Core
8051
Device Core Size
8b
Frequency (max)
25MHz
Total Internal Ram Size
4.25KB
# I/os (max)
22
Number Of Timers - General Purpose
4
Operating Supply Voltage (typ)
2.5/3.3V
Operating Supply Voltage (max)
3.6V
Operating Supply Voltage (min)
1.8V
On-chip Adc
18-chx10-bit
Instruction Set Architecture
CISC
Mounting
Surface Mount
Pin Count
42
Package Type
QFN EP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Operating Temperature
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1881-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI1000-C-GM
Manufacturer:
FSC
Quantity:
1 000
Company:
Part Number:
SI1000-C-GM
Quantity:
600
Part Number:
SI1000-C-GMR
Quantity:
6 500
Si1000/1/2/3/4/5
20.1.1. SmaRTClock Lock and Key Functions
The SmaRTClock Interface is protected with a lock and key function. The SmaRTClock Lock and Key Reg-
ister (RTC0KEY) must be written with the correct key codes, in sequence, before writes and reads to
RTC0ADR and RTC0DAT may be performed. The key codes are: 0xA5, 0xF1. There are no timing restric-
tions, but the key codes must be written in order. If the key codes are written out of order, the wrong codes
are written, or an indirect register read or write is attempted while the interface is locked, the SmaRTClock
interface will be disabled, and the RTC0ADR and RTC0DAT registers will become inaccessible until the
next system reset. Once the SmaRTClock interface is unlocked, software may perform any number of
accesses to the SmaRTClock registers until the interface is re-locked or the device is reset. Any write to
RTC0KEY while the SmaRTClock interface is unlocked will re-lock the interface.
Reading the RTC0KEY register at any time will provide the SmaRTClock Interface status and will not inter-
fere with the sequence that is being written. The RTC0KEY register description in SFR Definition 20.1 lists
the definition of each status code.
20.1.2. Using RTC0ADR and RTC0DAT to Access SmaRTClock Internal Registers
The SmaRTClock internal registers can be read and written using RTC0ADR and RTC0DAT. The
RTC0ADR register selects the SmaRTClock internal register that will be targeted by subsequent reads or
writes. Recommended instruction timing is provided in this section. If the recommended instruction timing
is not followed, then BUSY (RTC0ADR.7) should be checked prior to each read or write operation to make
sure the SmaRTClock Interface is not busy performing the previous read or write operation. A SmaRT-
Clock Write operation is initiated by writing to the RTC0DAT register. Below is an example of writing to a
SmaRTClock internal register.
1. Poll BUSY (RTC0ADR.7) until it returns 0 or follow recommended instruction timing.
2. Write 0x05 to RTC0ADR. This selects the internal RTC0CN register at SmaRTClock Address 0x05.
3. Write 0x00 to RTC0DAT. This operation writes 0x00 to the internal RTC0CN register.
A SmaRTClock Read operation is initiated by setting the SmaRTClock Interface Busy bit. This transfers
the contents of the internal register selected by RTC0ADR to RTC0DAT. The transferred data will remain in
RTC0DAT until the next read or write operation. Below is an example of reading a SmaRTClock internal
register.
1. Poll BUSY (RTC0ADR.7) until it returns 0 or follow recommended instruction timing.
2. Write 0x05 to RTC0ADR. This selects the internal RTC0CN register at SmaRTClock Address 0x05.
3. Write 1 to BUSY. This initiates the transfer of data from RTC0CN to RTC0DAT.
4. Poll BUSY (RTC0ADR.7) until it returns 0 or follow recommend instruction timing.
5. Read data from RTC0DAT. This data is a copy of the RTC0CN register. 
Note: The RTC0ADR and RTC0DAT registers will retain their state upon a device reset.
20.1.3. RTC0ADR Short Strobe Feature
Reads and writes to indirect SmaRTClock registers normally take 7 system clock cycles. To minimize the
indirect register access time, the Short Strobe feature decreases the read and write access time to 6 sys-
tem clocks. The Short Strobe feature is automatically enabled on reset and can be manually enabled/dis-
abled using the SHORT (RTC0ADR.4) control bit.
Recommended Instruction Timing for a single register read with short strobe enabled:
mov RTC0ADR, #095h
nop
nop
nop
mov A, RTC0DAT
192
Rev. 1.0