CJ1W-EIP21 Omron, CJ1W-EIP21 Datasheet - Page 109

no-image

CJ1W-EIP21

Manufacturer Part Number
CJ1W-EIP21
Description
Ethernet I/P Module
Manufacturer
Omron
Datasheet

Specifications of CJ1W-EIP21

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Registered Target
Node Table
(EtherNet/IP Unit to
CPU Unit) (n + 16 to n
+ 19)
Normal Target Node
Table (EtherNet/IP
Unit to CPU Unit)
(n+20 to n+23)
FINS/TCP Connection
Status
(EtherNet/IP Unit to
CPU Unit) (n+24)
CIO Area Allocations
Words n+16 to n+19 show the registration status of the target nodes that are
connected with the EtherNet/IP Unit as the originator.
These words show the status of nodes 0 to 63 only. If it is necessary to show
the status of nodes higher than node 63, select “user settings” as the layout
pattern. For details, refer to 4-4 User Settings Area.
Words n+20 to n+23 show the connection status of the target nodes that are
connected with the EtherNet/IP Unit as the originator. With revision 2 or
higher, the flag turns ON after all data for multiple connections for individual
target devices is refreshed in the CPU Unit. With revision 1, each flag immedi-
ately turns ON when all connections are established.
These words show the status of nodes 0 to 63 only. If it is necessary to show
the status of nodes higher than node 63, select “user settings” as the layout
pattern. For details, refer to 4-4 User Settings Area.
Word n+24 shows the status of FINS/TCP connections. For details, refer to
SECTION 8 FINS Communications.
n+16
n+17
n+18
n+19
n+20
n+21
n+22
n+23
n+24
---
---
0
Bit
Bit
Bit
15
Registered Target
Node Flags
Normal Target Node
Flags
FINS/TCP Connec-
tion 1
15
15
31
47
63
15
15
31
47
63
14
14
14
30
46
62
14
14
30
46
62
13
Name
Name
Name
13
13
29
45
61
13
13
29
45
61
12
12
12
28
44
60
12
12
28
44
60
11
11
11
27
43
59
11
11
27
43
59
10
10
10
26
42
58
10
10
26
42
58
9
9
25
41
57
9
25
41
57
9
9
ON
OFF
ON
OFF
ON
OFF
Status
Status
Status
8
8
24
40
56
8
24
40
56
8
8
7
23
39
55
23
39
55
7
7
7
7
6
Unit
Unit
Unit
Unit
Unit
Unit
22
38
54
22
38
54
Manipulated
Manipulated
Manipulated
6
6
5
6
6
21
37
53
21
37
53
4
5
5
5
5
by
by
by
3
20
36
52
20
36
52
4
4
4
4
2
19
35
51
19
35
51
3
3
3
3
1
18
34
50
18
34
50
2
2
2
2
Indicates that the node’s tag
data link is registered.
Indicates that the node’s tag
data link is not registered.
Revision 1: Flags immediately
turn ON when all connections
are established.
Revision 2 or higher: Flags turn
ON after all data for multiple
connections for the target
device is refreshed in the CPU
Unit.
Indicates that the connection is
not established
Turned ON by the Unit when a
connection is established.
Turned OFF by the Unit when
the connection is terminated.
0
17
33
49
17
33
49
1
1
1
1
16
32
48
16
32
48
0
0
0
0
Unit operation
Unit operation
Unit operation
Section 4-2
81