CJ1W-EIP21 Omron, CJ1W-EIP21 Datasheet - Page 417

no-image

CJ1W-EIP21

Manufacturer Part Number
CJ1W-EIP21
Description
Ethernet I/P Module
Manufacturer
Omron
Datasheet

Specifications of CJ1W-EIP21

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Example of Additional Status in case that General Status Is 01 Hex.
(Status of Connection Manager Object)
CIP Message Communications
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
General Status
(hex)
0100
0103
0106
0107
0108
0109
0110
0111
0113
0114
0115
0116
0117
0118
0119
011A
011B
0203
0204
0205
0206
0207
0301
0302
0303
0304
0311
0312
0315
0316
0317
0318
0319
031A
031B
031C
031D
031F
0320-07FF
Status (hex)
Additional
Connection in Use or Duplicate Forward Open.
Transport Class and Trigger combination not supported
Ownership Conflict
Connection not found at target application.
Invalid Connection Type. Indicates a problem with either the Connection Type or Prior-
ity of the Connection.
Invalid Connection Size
Device not configured
RPI not supported. May also indicate problem with connection time-out multiplier, or
production inhibit time.
Connection Manager cannot support any more connections
Either the Vendor Id or the Product Code in the key segment did not match the device
Product Type in the key segment did not match the device
Major or Minor Revision information in the key segment did not match the device
Invalid Connection Point
Invalid Configuration Format
Connection request fails since there is no controlling connection currently open.
Target Application cannot support any more connections
RPI is smaller than the Production Inhibit Time.
Connection cannot be closed since the connection has timed out
Unconnected Send timed out waiting for a response.
Parameter Error in Unconnected Send Service
Message too large for Unconnected message service
Unconnected acknowledge without reply
No buffer memory available
Network Bandwidth not available for data
No Tag filters available
Not Configured to send real-time data
Port specified in Port Segment Not Available
Link Address specified in Port Segment Not Available
Invalid Segment Type or Segment Value in Path
Path and Connection not equal in close
Either Segment not present or Encoded Value in Network Segment is invalid.
Link Address to Self Invalid
Resources on Secondary Unavailable
Connection already established
Direct connection already established
Miscellaneous
Redundant connection mismatch
No connection resources exist for target path
Vendor specific
Explanation
Appendix D
389

Related parts for CJ1W-EIP21