CJ1W-EIP21 Omron, CJ1W-EIP21 Datasheet - Page 125

no-image

CJ1W-EIP21

Manufacturer Part Number
CJ1W-EIP21
Description
Ethernet I/P Module
Manufacturer
Omron
Datasheet

Specifications of CJ1W-EIP21

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
IP Addresses in FINS Communications
Automatic Generation
(Static)
IP Address Table Method
Personal computer
Local FINS node number
Local IP address
IP address
IP address
Must be fixed.
Must be fixed.
With the static method as well, the following values are set for addresses in
the internal table when the EtherNet/IP Unit or built-in EtherNet/IP port is
turned ON or restarted.
With the static method, however, data in an internal table that has been gener-
ated is not freely changed.
With this method, FINS node addresses are converted to IP addresses based
on a preset correspondence table (IP address table).
The IP address table is set on the FINS/UDP Tab Page of the Edit Parameters
Dialog Box of the CX-Programmer. Nodes can be registered even if they are
in different segments and have different network IDs
The internal table will be as follows:
With the IP address table method, records of FINS nodes registered to the IP
address table are not changed dynamically. When the Unit is turned ON or
restarted, the IP addresses of remote FINS nodes registered with an IP
address of 0.0.0.0 can be changed dynamically according to FINS messages
received from remote nodes. This can be used effectively when the remote
node is a device such as a personal computer and IP addresses are dynami-
cally changed by a method such as DHCP.
FINS command
FINS response
• Remote IP address:
• Remote UDP port number: UDP port number set for local Unit
• Connection method:
• FINS Node Address Registered to IP Address Table
• FINS Node Address Not Registered to IP Address Table
The following address is registered to the internal table.
The following address is registered to the internal table.
• Remote IP address:
• Remote UDP port number: UDP port number set for local Unit
• Connection method:
• Remote IP address:
• Remote UDP port number: UDP port number set for local Unit
• Connection method:
EtherNet/IP Unit
Remote IP address
Automatic generation
(static setting)
Internal table
Local IP address network number + remote
FINS node address
FINS/UDP
IP address registered to IP address table
FINS/UDP
0.0.0.0
FINS/UDP
Local IP address
Ethernet (EtherNet/IP)
CPU Unit
Remote FINS node number
Local FINS node number
Section 5-2
97