CJ1W-EIP21 Omron, CJ1W-EIP21 Datasheet - Page 281

no-image

CJ1W-EIP21

Manufacturer Part Number
CJ1W-EIP21
Description
Ethernet I/P Module
Manufacturer
Omron
Datasheet

Specifications of CJ1W-EIP21

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Receiving Explicit Messages
Service Code
FFFE
0008B
009A
009B
02F0
0300 to 035F
00A0 to 00A1
0500 to 055F
00E7
00F7
0200 to 020F
0400 to 040F
4101 to 42FF
Error code
10
Note The specified code for the above operating modes are 1-word (2-byte
Note Error clear codes are 1-word (2-byte) data, so the above codes are
(Hex)
• CPU Operating Mode (Attribute ID = 64 Hex)
• Clearing CPU Unit Errors (when Attribute ID = 65 Hex)
Class ID
(2F)
Changes the CPU Unit operating mode.
The Attribute Values are as follows:
0001 Hex: PROGRAM mode; 0002 Hex: MONITOR mode;
0004 Hex: RUN mode
Clears any fatal or non-fatal errors in the CPU Unit. Sets the error clear
code to Attribute Value. The error clear codes are listed in the following
table.
C4
data, and are specified with the low byte first. For example, for PRO-
GRAM mode, the code is specified as 01 Hex followed by 00 Hex. Ac-
cordingly, the low to high bytes for the above codes are set as high
to low bytes in I/O memory, when setting the codes as data for oper-
and S of CMND(490).
specified with the low byte first. The low to high bytes for the above
codes are set as high to low bytes in I/O memory, when setting the
codes as data for operand S of CMND(490). For example, to specify
battery error 00F7 Hex, specify the error code as F7 Hex followed by
00 Hex, as shown in the following diagram.
Instance ID
00
Attribute ID
Current error (clears the highest priority error)
Interrupt task error
Basic I/O error
PLC Setup error
Inner Board non-fatal error
Special I/O Unit error
SYSMAC BUS error
Special I/O Unit settings error
I/O verification error
When registered and actual I/O tables are different
When disconnecting or connecting I/O Units
Battery error
CS/CJ-series CPU Bus Unit error (last 2 digits are binary code for
the Unit No.)
For parity errors generated when data transferred between CS/CJ-
series CPU Bus Unit and CPU Unit
For watchdog timer errors in CS/CJ-series CPU Bus Unit
CPU Bus settings error (last 2 digits are binary code for the Unit
No.)
System error (FAL): FAL instruction executed
65
Attribute Value
F7
00
The class ID depends on the unit version.
Version 2.0 or later: The class ID is C4.
Version 1.0: The class ID is 2F.
Data cleared
Section 9-2
253