CJ1W-EIP21 Omron, CJ1W-EIP21 Datasheet - Page 232
![no-image](/images/manufacturer_photos/0/4/494/omron_sml.jpg)
CJ1W-EIP21
Manufacturer Part Number
CJ1W-EIP21
Description
Ethernet I/P Module
Manufacturer
Omron
Datasheet
1.CJ1W-EIP21.pdf
(469 pages)
Specifications of CJ1W-EIP21
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
- Current page: 232 of 469
- Download datasheet (10Mb)
FINS/TCP Method
FINS/TCP
Communications
Procedure
204
Example:
IP address C
FINS node number A
Remote node No. received
Connection established
Personal computer
FINS frame sent
Local node No. sent
Active open
(Client)
Note
FINS node number A sent
FINS node number B sent
FINS/TCP Connection Status (Word n+24)
While a connection with a remote node is established, the bit corresponding to
the FINS/TCP connection status turns ON in the section of the CPU Bus Unit
words allocated in the CIO Area. The bit turns OFF if the connection is termi-
nated by a communications error or a FINS command (i.e., FINS/TCP CON-
NECTION REMOTE NODE CHANGE REQUEST).
The starting word of the FINS/TCP Connection Status Area is different in the
CS1W-ETN21 and CJ1W-ETN21 Ethernet Units; it is n+23 in the Ethernet
Units. If a ladder program using FINS/TCP communications was created for
Ethernet Units, and is being reused for EtherNet/IP Units and built-in Ether-
Net/IP ports, change the word starting word address for this area from n+23 to
n+24.
With FINS/TCP, FINS node addresses are exchanged immediately after a
connection is established. This makes it possible to determine the FINS node
addresses to which the 16 connection numbers, and to manage them in an
internal table.
After a connection has been established as a FINS/TCP server, it is termi-
nated in the following ways.
Connection request (C→S)
Full duplex communications
• When the connection is closed by the client.
• When a FINS command to close the connection (FINS/TCP CONNEC-
• When there is no response from the client when the keep-alive function is
TION REMOTE NODE CHANGE REQUEST) is sent by the client.
in effect.
n+24
*: Bit 15 corresponds to connection No. 16, bit 00 to connection No. 1, etc.
15 14 13 12 11 10 09
Example:
IP address S
FINS node number B
Remote node No. received
Connection established
FINS frame sent
Local node No. sent
Ethernet/IP Unit
Passive open
(Server)
08
07 06
Connection established
FINS node numbers exchanged
Normal data communications
05 04 03 02 01 00
Section 8-3
Related parts for CJ1W-EIP21
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
![CJ1W-NC214](/images/manufacturer_photos/0/4/494/omron_tmb.jpg)
Part Number:
Description:
High Speed Pulse Train 2 Axes
Manufacturer:
Omron
Datasheet:
![CJ1W-NC234](/images/manufacturer_photos/0/4/494/omron_tmb.jpg)
Part Number:
Description:
High Speed Pulse Train 2 Axes
Manufacturer:
Omron
Datasheet:
![CJ1W-NC414](/images/manufacturer_photos/0/4/494/omron_tmb.jpg)
Part Number:
Description:
High Speed Pulse Train 4 Axes
Manufacturer:
Omron
Datasheet:
![CJ1W-CT021](/images/manufacturer_photos/0/4/494/omron_tmb.jpg)
Part Number:
Description:
HIGH SPEED COUNTER 500Khz 2 CH
Manufacturer:
Omron
Datasheet:
![G6S-2G](/images/no-image3.png)
Part Number:
Description:
G6S-2GLow Signal Relay
Manufacturer:
Omron Corporation
Datasheet:
![G3NE-220T](/images/no-image3.png)
Part Number:
Description:
Compact, Low-cost, SSR Switching 5 to 20 A
Manufacturer:
Omron Corporation
Datasheet:
![G6K-2G-Y](/images/no-image3.png)
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
![G4A-1A-E](/images/no-image3.png)
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
![G5NB-1A-E](/images/no-image3.png)
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
![G6B-2114P-US](/images/no-image3.png)
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet: