Specifications of LAN9303-ABZJ

Controller Type
Ethernet Switch Controller
Interface
SMBus (2-Wire/I²C)
Voltage - Supply
3 V ~ 3.6 V
Current - Supply
190mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
56-QFN
Product
Ethernet Switches
Standard Supported
Yes
Data Rate
10 Mbps/100 Mbps
Supply Voltage (max)
3.6 V
Supply Voltage (min)
3 V
Supply Current (max)
0.19 A (Typ)
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
For Use With
638-1095 - EVALUATION BOARD FOR LAN9303
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
638-1082

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LAN9303-ABZJ
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Revision 1.4 (07-07-10)
BITS
17:0
Port Default VID and Priority
When the port VID table is selected (PVIDnVLAN=1 of the
VLAN Command Register
the default VID for the port and bits 14:12 specify the default priority. All
other bits of this field are reserved. These bits are used when a packet is
received without a VLAN tag or with a NULL VLAN ID. The default VID is
also used when the
also used when no other priority choice is selected. By default, the VID for
all three ports is 1 and the priority for all three ports is 0.
Note:
VLAN Data
When the VLAN table is selected (PVIDnVLAN=0 of the
VLAN Command Register
table entry as follows:
BITS
11:0
17
16
15
14
13
12
Values of 0 and FFFh should not be used since they are special
VLAN IDs per the IEEE 802.3Q specification.
Member Port 2
Indicates the configuration of Port 2 for this VLAN entry.
1 = Member - Packets with a VID that matches this entry
are allowed on ingress. The port is a member of the
broadcast domain on egress.
0 = Not a Member - Packets with a VID that matches this
entry are filtered on ingress unless the
bit in the
(SWE_ADMT_N_MEMBER)
not a member of the broadcast domain on egress.
Un-Tag Port 2
When this bit is set, packets with a VID that matches this
entry will have their tag removed when re-transmitted on
Port 2 when it is designated as a Hybrid port via the
Manager Egress Port Type Register
(BM_EGRSS_PORT_TYPE).
Member Port 1
See description for Member Port 2.
Un-Tag Port 1
See description for Un-Tag Port 2.
Member Port 0
See description for Member Port 2.
Un-Tag Port 0
See description for Un-Tag Port 2.
VID
These bits specify the VLAN ID associated with this VLAN
entry.
To disable a VLAN entry, a value of 0 should be used.
Note:
Note:
Switch Engine Admit Non Member Register
802.1Q VLAN Disable
A value of 0 is considered a NULL VLAN and
should not normally be used other than to
disable a VLAN entry.
A value of 3FFh is considered reserved by IEEE
802.1Q and should not be used.
(SWE_VLAN_CMD)), bits 11:0 of this field specify
(SWE_VLAN_CMD)), the bits form the VLAN
DESCRIPTION
DESCRIPTION
Small Form Factor Three Port 10/100 Managed Ethernet Switch with Single MII/RMII/Turbo MII
is set for this port. The port is
DATASHEET
Admit Non Member
bit is set. The default priority is
282
Buffer
Switch Engine
Switch Engine
DEFAULT
000h
0b
0b
0b
0b
0b
0b
TYPE
R/W
SMSC LAN9303/LAN9303i
DEFAULT
Datasheet
0b

Related parts for LAN9303-ABZJ