LAN9303-ABZJ SMSC, LAN9303-ABZJ Datasheet - Page 62

IC ETHER SW 3PORT 16BIT 56QFN

LAN9303-ABZJ

Manufacturer Part Number
LAN9303-ABZJ
Description
IC ETHER SW 3PORT 16BIT 56QFN
Manufacturer
SMSC
Datasheets

Specifications of LAN9303-ABZJ

Controller Type
Ethernet Switch Controller
Interface
SMBus (2-Wire/I²C)
Voltage - Supply
3 V ~ 3.6 V
Current - Supply
190mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
56-QFN
Product
Ethernet Switches
Standard Supported
Yes
Data Rate
10 Mbps/100 Mbps
Supply Voltage (max)
3.6 V
Supply Voltage (min)
3 V
Supply Current (max)
0.19 A (Typ)
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
For Use With
638-1095 - EVALUATION BOARD FOR LAN9303
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
638-1082

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LAN9303-ABZJ
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Revision 1.4 (07-07-10)
6.2.3
Flow Control Enable Logic
Each Switch Fabric port (0,1,2) is provided with two flow control enable inputs per port, one for
transmission and one for reception. Flow control on transmission allows the transmitter to generate
back pressure in half-duplex mode, and pause packets in full-duplex. Flow control in reception enables
the reception of pause packets to pause transmissions.
The state of these enables is based on the state of the port’s duplex and Auto-negotiation settings and
the values of the corresponding Manual Flow Control register
(MANUAL_FC_1),
Control Register
When in half-duplex mode, the transmit flow control (back pressure) enable is determined directly by
the BP_EN_x bit of the port’s manual flow control register. When Auto-negotiation is disabled, or the
MANUAL_FC_x bit of the port’s manual flow control register is set, the switch port flow control enables
during full-duplex are determined by the TX_FC_x and RX_FC_x bits of the port’s manual flow control
register. When Auto-negotiation is enabled and the MANUAL_FC_x bit is cleared, the switch port flow
control enables during full-duplex are determined by Auto-negotiation.
Figure 6.2 Switch Fabric CSR Read Access Flow Diagram
(MANUAL_FC_0)).
CSR Read
Port 2 Manual Flow Control Register
Read Data
Command
Command
Register
Register
Register
Read
Write
Idle
CSR_BUSY = 0
Small Form Factor Three Port 10/100 Managed Ethernet Switch with Single MII/RMII/Turbo MII
CSR_BUSY = 1
DATASHEET
Table 6.1
62
CSR Read Auto
details the Switch Fabric flow control enable logic.
Increment /
Decrement
Read Data
Command
Command
Command
Register
Register
Register
Register
Write
Read
Write
data?
Idle
last
CSR_BUSY = 0
Yes
(MANUAL_FC_2), or
No
CSR_BUSY = 1
(Port 1 Manual Flow Control Register
Read Data
Register
SMSC LAN9303/LAN9303i
Port 0 Manual Flow
Datasheet

Related parts for LAN9303-ABZJ