MT9072 Zarlink Semiconductor, Inc., MT9072 Datasheet - Page 193

no-image

MT9072

Manufacturer Part Number
MT9072
Description
Octal T1-E1-J1 Framer
Manufacturer
Zarlink Semiconductor, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MT9072AV
Manufacturer:
ZARLINK
Quantity:
56
Part Number:
MT9072AV2
Manufacturer:
TRIQUINT
Quantity:
56
Part Number:
MT9072AV2
Manufacturer:
ZARLINK
Quantity:
20 000
Advance Information
15-4
Bit
Bit
2
1
0
3
2
1
0
Table 176 - CAS, National, CRC-4 Local and Timer Latched Status Register (Address Y26) (E1)
ONESECL One Second Timer Status Latch. When the ONESEC status bit (register address Y11)
BSYNCP
Name
LOSSP
T2L
T1L
Name
Table 177 - Performance Persistent Latched Status Register (Address Y27) (E1)
RAIP
AISP
#
Timer 2 Latch. When the CRC-4 T2 (10ms) status bit (register address Y11) toggles from
zero to one, this status bit is latched to one. This bit is set on a basic frame (FPi) basis. This
bit is cleared when either this register, or the corresponding interrupt status register (register
address Y36) is read.
Timer 1 Latch. When the CRC-4 T1 (100ms) status bit (register address Y11) toggles from
zero to one, this status bit is latched to one. This bit is set on a basic frame (FPi) basis. This
bit is cleared when either this register, or the corresponding interrupt status register (register
address Y36) is read.
toggles from zero to one, this status bit is latched to one. This bit is set on a basic frame (FPi)
basis. This bit is cleared when either this register, or the corresponding interrupt status
register (register address Y36) is read.
not used.
Remote Alarm Indication Status Persistent Latch. When the RAI (A) status bit (register
address Y12 and Y13) toggles from zero to one, this status bit is latched to one. This bit is
cleared when this register is read while the RAI status bit is zero.
Alarm Indication Status Signal Persistent. When the AIS status bit (register address
Y12) toggles from zero to one, this status bit is latched to one. This bit is cleared when this
register is read while the AIS status bit is zero.
Loss of Signal Status Indication Persistent Latch. When the LOSS status bit (register
address Y12) toggles from zero to one, this status bit is latched to one. This bit is cleared
when this register is read while the LOSS status bit is zero.
Receive Basic Frame Alignment Persistent Latch. When the BSYNC status bit (register
address Y10) toggles from zero to one, this status bit is latched to one. This bit is cleared
when this register is read while the BSYNC status bit is zero.
Functional Description
Functional Description
MT9072
193

Related parts for MT9072