peb2256 Infineon Technologies Corporation, peb2256 Datasheet - Page 358

no-image

peb2256

Manufacturer Part Number
peb2256
Description
E1/t1/j1 Framer And Line Interface Component For Long And Short Haul Applications
Manufacturer
Infineon Technologies Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
peb2256H
Manufacturer:
Infineon
Quantity:
5
Part Number:
peb2256H-V12
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
peb2256HV1.2
Manufacturer:
INFINEON
Quantity:
5 510
Part Number:
peb2256HV1.2
Manufacturer:
SIEMENS
Quantity:
3
Part Number:
peb2256HV1.2
Manufacturer:
XILINX
0
Part Number:
peb2256HV1.4
Manufacturer:
INFINEON
Quantity:
1 831
Part Number:
peb2256R V1.2
Quantity:
5 510
CRCI
XCRCI
RDIS
RCO(10:8)
Data Sheet
Release
Depending on the selected multiframe format the alarm is reset when
FALC56 does not detect
– the “bit 2 = 0" condition for three consecutive pulse frames
– the "FS-bit" condition for three consecutive multiframes (F12),
– the "DL pattern" for three times in a row (ESF).
Automatic CRC6 Bit Inversion
If set, all CRC bits of one outgoing extended multiframe are inverted
in case a CRC error is flagged for the previous received multiframe.
This function is logically ored with RC0.XCRCI.
Transmit CRC6 Bit Inversion
If set, the CRC bits in the outgoing data stream are inverted before
transmission. This function is logically ored with RC0.CRCI.
Receive Data Input Sense
Digital interface, dual-rail:
0 =
1 =
Digital Interface, CMI:
0 =
1 =
Receive Offset/Receive Frame Marker Offset
Depending on the RP(A to D) pin function different offsets can be
programmed. The SYPR and the RFM pin function cannot be
selected in parallel.
Receive Offset (PC(4:1).RPC(2:0) = 000)
Initial value loaded into the receive bit counter at the trigger edge of
SCLKR when the synchronous pulse on port SYPR is active.
Calculation of delay time T (SCLKR cycles) depends on the value X
of the receive offset register RC(1:0). Refer to register RC1.
(all formats if selected),
Inputs RDIP/RDIN are active low
Inputs RDIP/RDIN are active high
Input ROID is active high
Input ROID is active low
358
T1/J1 Registers
FALC56 V1.2
PEB 2256
2002-08-27

Related parts for peb2256