peb2256 Infineon Technologies Corporation, peb2256 Datasheet - Page 432

no-image

peb2256

Manufacturer Part Number
peb2256
Description
E1/t1/j1 Framer And Line Interface Component For Long And Short Haul Applications
Manufacturer
Infineon Technologies Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
peb2256H
Manufacturer:
Infineon
Quantity:
5
Part Number:
peb2256H-V12
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
peb2256HV1.2
Manufacturer:
INFINEON
Quantity:
5 510
Part Number:
peb2256HV1.2
Manufacturer:
SIEMENS
Quantity:
3
Part Number:
peb2256HV1.2
Manufacturer:
XILINX
0
Part Number:
peb2256HV1.4
Manufacturer:
INFINEON
Quantity:
1 831
Part Number:
peb2256R V1.2
Quantity:
5 510
LFA
MFAR
LMFA
AIS
LOS
RAR
RA
Data Sheet
Loss of Frame Alignment
The framer has lost synchronization and bit FRS0.LFA is set.
It is set during alarm simulation.
Multiframe Alignment Recovery
Set when the framer has reached multiframe alignment in F12 or F72
format. With the negative transition of bit FRS0.LMFA this bit is set. It
is set during alarm simulation.
Loss of Multiframe Alignment
Set when the framer has lost the multiframe alignment in F12 or F72
format. With the positive transition of bit FRS0.LMFA this bit is set. It
is set during alarm simulation.
Alarm Indication Signal (Blue Alarm)
This bit is set when an alarm indication signal is detected and bit
FRS0.AIS is set. If GCR.SCI is set high this interrupt status bit is
activated with every change of state of FRS0.AIS.
It is set during alarm simulation.
Loss-of-Signal (Red Alarm)
This bit is set when a loss-of-signal alarm is detected in the received
data stream and FRS0.LOS is set. If GCR.SCI is set high this interrupt
status bit is activated with every change of state of FRS0.LOS.
It is set during alarm simulation.
Remote Alarm Recovery
Set if a remote alarm (yellow alarm) is cleared and bit FRS0.RRA is
reset. It is set also after alarm simulation is finished and no remote
alarm is detected.
Remote Alarm
A remote alarm (yellow alarm) is detected. Set with the rising edge of
bit FRS0.RRA. It is set during alarm simulation.
432
T1/J1 Registers
FALC56 V1.2
PEB 2256
2002-08-27