peb2256 Infineon Technologies Corporation, peb2256 Datasheet - Page 429

no-image

peb2256

Manufacturer Part Number
peb2256
Description
E1/t1/j1 Framer And Line Interface Component For Long And Short Haul Applications
Manufacturer
Infineon Technologies Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
peb2256H
Manufacturer:
Infineon
Quantity:
5
Part Number:
peb2256H-V12
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
peb2256HV1.2
Manufacturer:
INFINEON
Quantity:
5 510
Part Number:
peb2256HV1.2
Manufacturer:
SIEMENS
Quantity:
3
Part Number:
peb2256HV1.2
Manufacturer:
XILINX
0
Part Number:
peb2256HV1.4
Manufacturer:
INFINEON
Quantity:
1 831
Part Number:
peb2256R V1.2
Quantity:
5 510
RSC
CRC6
PDEN
RPF
Data Sheet
Received Signaling Information Changed
This interrupt bit is set during each multiframe in which signaling
information on at least one channel changes its value from the
previous multiframe. This interrupt only occurs in the synchronous
state. The registers RS(12:1) should be read within the next 3 ms
otherwise the contents is lost.
Receive CRC6 Error
0 =
1 =
Pulse-Density Violation
The pulse-density violation of the received data stream defined by
ANSI T1. 403 is violated. More than 14 consecutive zeros or less than
N ones in each and every time window of 8 × (N+1) data bits (N = 23)
are detected. If GCR.SCI is set high this interrupt status bit is
activated with every change of state of FRS1.PDEN.
Receive Pool Full - HDLC Channel 1
32 bytes of a frame have arrived in the receive FIFO. The frame is not
yet received completely.
No CRC6 error occurs.
The CRC6 check of the last received multiframe failed.
429
T1/J1 Registers
FALC56 V1.2
PEB 2256
2002-08-27

Related parts for peb2256