MC9S12XDP512MAG Freescale, MC9S12XDP512MAG Datasheet - Page 549

MC9S12XDP512MAG

Manufacturer Part Number
MC9S12XDP512MAG
Description
Manufacturer
Freescale
Datasheet

Specifications of MC9S12XDP512MAG

Cpu Family
HCS12
Device Core Size
16b
Frequency (max)
40MHz
Interface Type
CAN/I2C/SCI/SPI
Total Internal Ram Size
32KB
# I/os (max)
119
Number Of Timers - General Purpose
12
Operating Supply Voltage (typ)
2.5/5V
Operating Supply Voltage (max)
2.75/5.5V
Operating Supply Voltage (min)
2.35/3.15V
On-chip Adc
2(24-chx10-bit)
Instruction Set Architecture
CISC
Operating Temp Range
-40C to 125C
Operating Temperature Classification
Automotive
Mounting
Surface Mount
Pin Count
144
Package Type
LQFP
Program Memory Type
Flash
Program Memory Size
512KB
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC9S12XDP512MAG
Manufacturer:
FREESCALE
Quantity:
5 530
Part Number:
MC9S12XDP512MAG
Manufacturer:
Exar
Quantity:
20
Part Number:
MC9S12XDP512MAG
Manufacturer:
FREESCALE
Quantity:
3 450
Part Number:
MC9S12XDP512MAG
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC9S12XDP512MAG
Manufacturer:
FREESCALE
Quantity:
3 450
13.3.0.8
Read: Anytime
Write: Anytime
Freescale Semiconductor
Reset
Reset
Reset
Reset
PLD[15:0]
Field
W
W
W
W
15:0
R
R
R
R
PLD15 PLD14 PLD13 PLD12 PLD11 PLD10 PLD9 PLD8 PLD7 PLD6 PLD5 PLD4 PLD3 PLD2 PLD1 PLD0
PLD15 PLD14 PLD13 PLD12 PLD11 PLD10 PLD9 PLD8 PLD7 PLD6 PLD5 PLD4 PLD3 PLD2 PLD1 PLD0
PLD15 PLD14 PLD13 PLD12 PLD11 PLD10 PLD9 PLD8 PLD7 PLD6 PLD5 PLD4 PLD3 PLD2 PLD1 PLD0
PLD15 PLD14 PLD13 PLD12 PLD11 PLD10 PLD9 PLD8 PLD7 PLD6 PLD5 PLD4 PLD3 PLD2 PLD1 PLD0
15
15
15
15
0
0
0
0
PIT Load Bits 15:0 — These bits set the 16-bit modulus down-counter load value. Writing a new value into the
PITLD register must be a 16-bit access, to ensure data consistency. It will not restart the timer. When the timer
has counted down to zero the PTF time-out flag will be set and the register value will be loaded. The PFLT bits
in the PITFLT register can be used to immediately update the count register with the new value if an immediate
load is desired.
PIT Load Register 0 to 3 (PITLD0–3)
14
14
14
14
0
0
0
0
13
13
13
13
0
0
0
0
12
12
12
12
0
0
0
0
Figure 13-11. PIT Load Register 0 (PITLD0)
Figure 13-12. PIT Load Register 1 (PITLD1)
Figure 13-13. PIT Load Register 2 (PITLD2)
Figure 13-14. PIT Load Register 3 (PITLD3)
Table 13-8. PITLD0–3 Field Descriptions
MC9S12XDP512 Data Sheet, Rev. 2.21
11
11
11
11
0
0
0
0
10
10
10
10
0
0
0
0
0
0
0
0
9
9
9
9
Description
0
0
0
0
8
8
8
8
0
0
0
0
7
7
7
7
Chapter 13 Periodic Interrupt Timer (S12PIT24B4CV1)
0
0
0
0
6
6
6
6
0
0
0
0
5
5
5
5
0
0
0
0
4
4
4
4
0
0
0
0
3
3
3
3
0
0
0
0
2
2
2
2
0
0
0
0
1
1
1
1
0
0
0
0
0
0
0
0
549