UPD78F0386GK-8EU-A Renesas Electronics America, UPD78F0386GK-8EU-A Datasheet - Page 233

no-image

UPD78F0386GK-8EU-A

Manufacturer Part Number
UPD78F0386GK-8EU-A
Description
MCU 96KB FLASH 5KB RAM
Manufacturer
Renesas Electronics America
Series
78K0/Lx2r
Datasheet

Specifications of UPD78F0386GK-8EU-A

Core Processor
78K/0
Core Size
8-Bit
Speed
20MHz
Connectivity
3-Wire SIO, I²C, LIN, UART/USART
Peripherals
LCD, LVD, POR, PWM, WDT
Number Of I /o
26
Program Memory Size
96KB (96K x 8)
Program Memory Type
FLASH
Ram Size
5K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Data Converters
-
<10> By performing the procedures above, an arbitrary carrier clock is obtained. To stop the count operation,
clear TMHE1 to 0.
If the setting value of the CMP01 register is N, the setting value of the CMP11 register is M, and the count
clock frequency is f
Cautions 1. Be sure to set the CMP11 register when starting the timer count operation (TMHE1 = 1)
Remarks 1. For the setting of the output pin, see 8.3 (3) Port mode register 1 (PM1).
Carrier clock output cycle = (N + M + 2)/f
Duty = High-level width/carrier clock output width = (M + 1)/(N + M + 2)
2. For how to enable the INTTMH1 signal interrupt, see CHAPTER 19
2. Set so that the count clock frequency of TMH1 becomes more than 6 times the count
3. Set the values of the CMP01 and CMP11 registers in a range of 01H to FFH.
4. The set value of the CMP11 register can be changed while the timer counter is
5. Be sure to set the RMC1 bit before the count operation is started.
FUNCTIONS.
after the timer count operation was stopped (TMHE1 = 0) (be sure to set again even if
setting the same value to the CMP11 register).
clock frequency of TM51.
operating. However, it takes the duration of three operating clocks (signal selected by
the CKS12 to CKS10 bits of the TMHMD1 register) since the value of the CMP11
register has been changed until the value is transferred to the register.
CNT
, the carrier clock output cycle and duty are as follows.
CHAPTER 8 8-BIT TIMERS H0 AND H1
User’s Manual U17504EJ2V0UD
CNT
INTERRUPT
231