Specifications of M30262F8GP#U7

Core Processor
M16C/60
Core Size
16-Bit
Speed
20MHz
Connectivity
I²C, IEBus, SIO, UART/USART
Peripherals
DMA, WDT
Number Of I /o
38
Program Memory Size
64KB (64K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
48-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
M30262F8GP#U7M30262F8GP
Manufacturer:
NA
Quantity:
20 000
Company:
Part Number:
M30262F8GP#U7M30262F8GP#D3
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
M30262F8GP#U7M30262F8GP#D5
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
M30262F8GP#U7M30262F8GP#U3
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
M30262F8GP#U7M30262F8GP#U5
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Status Transition of BCLK
Status Transition of BCLK
Power dissipation can be reduced and low-voltage operation achieved by changing the count source for
BCLK. Table 1.8.3 shows the operating modes corresponding to the settings of system clock control
registers 0 and 1.
When reset, the device starts in division by 8 mode. The main clock division select bit 0 (bit 6 at address
0006
from high-speed/medium-speed mode to stop mode, shifting to low power dissipation mode and at a reset.
When shifting from high-speed/medium-speed mode to low-speed mode, the value before high-speed/
medium-speed mode is retained. The following shows the operational modes of BCLK.
(1) Division by 2 mode
(2) Division by 4 mode
(3) Division by 8 mode
(4) Division by 16 mode
(5) No-division mode
(6) Low-speed mode
(7) Low power dissipation mode
The main clock is divided by 2 to obtain the BCLK.
The main clock is divided by 4 to obtain the BCLK.
The main clock is divided by 8 to obtain the BCLK. When reset, the device starts operating from this
mode. Before the user can go from this mode to no division mode, division by 2 mode, or division by 4
mode, the main clock must be oscillating stably. When going to low-speed or lower power consumption
mode, make sure the sub-clock is oscillating stably.
The main clock is divided by 16 to obtain the BCLK.
The main clock is divided by 1 to obtain the BCLK.
f
transferring from this mode to another or vice versa. At least 2 to 3 seconds are required after the sub-
clock starts. Therefore, the program must be written to wait until this clock has stabilized immediately
after powering up and after stop mode is cancelled.
f
C
C
is used as the BCLK. Note that oscillation of both the main and sub-clocks must have stabilized before
is the BCLK and the main clock is stopped.
16
) and the X
Preliminary Specifications Rev. 0.9
Specifications in this manual are tentative and subject to change.
IN
-X
OUT
drive capacity select bit (bit 5 at address 0007
Renesas Technology Corp.
SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER
16
) change to “1” when shifting
M16C/26 Group