WG82574IT S LBAC Intel, WG82574IT S LBAC Datasheet - Page 223

no-image

WG82574IT S LBAC

Manufacturer Part Number
WG82574IT S LBAC
Description
CONTROLLER, ENET, INTEL 82574IT, 64PQFN
Manufacturer
Intel
Datasheet

Specifications of WG82574IT S LBAC

Ethernet Type
IEEE 802.3, IEEE 802.3u, IEEE 802.3ab
Supply Voltage Range
3V To 3.6V
Operating Temperature Range
-40°C To +85°C
Digital Ic Case Style
QFN
No. Of Pins
64
Package / Case
QFN
Interface Type
I2C, JTAG, PCI, SPI
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
System Manageability—82574 GbE Controller
8.8.1.5
Note:
Table 57.
8.8.1.6
Note:
Management Control
Keep PHY Link Up
Update Manageability
Filter Parameters
Function
Function
Parameter
Management Control
This command is used to set generic manageability parameters. The parameters list is
shown in Management Control Command Parameters/Content. The command is 0xC1
stating that it is a Management Control command. The first data byte is the parameter
number and the data after words (length and content) are parameter specific as shown
in Management Control Command Parameters/Content.
If the parameter that the MC sets is not supported by the 82574L. The 82574L does not
NACK the transaction. After the transaction ends, the 82574L discards the data and
asserts a transaction abort status.
The Management Control command format is as follows:
Management Control Command Parameters/Content
Update Management Receive Filter Parameters
This command is used to set the manageability receive filters parameters. The
command is 0xCC. The first data byte is the parameter number and the data that
follows (length and content) are parameter specific as listed in management RCV filter
parameters.
If the parameter that the MC sets is not supported by the 82574L, then the 82574L
does not NACK the transaction. After the transaction ends, the 82574L discards the
data and asserts a transaction abort status.
The update management RCV receive filter parameters command format is as follows:
0xC1
0xCC
Command
Command
0x00
#
A single byte parameter:
Data 2:
Bit 0: Set to indicate that the PHY link for this port should be
kept up throughout system resets. This is useful when the
server is reset and the MC needs to keep connectivity for a
manageability session.
Bit [7:1] Reserved.
0b: Disabled.
1b: Enabled.
N
N
Count
Count
Byte
Byte
Parameter
Number
Parameter
Number
Data 1
Data 1
Parameter Data
Parameter Dependent
Parameter Dependent
Data
Data 2
2
Data N
Data N