TXC-04222-AIOG Transwitch Corporation, TXC-04222-AIOG Datasheet - Page 153

no-image

TXC-04222-AIOG

Manufacturer Part Number
TXC-04222-AIOG
Description
Manufacturer
Transwitch Corporation
Datasheet

Specifications of TXC-04222-AIOG

Screening Level
Industrial
Package Type
BGA
Lead Free Status / Rohs Status
Not Compliant
Address
057
058
059
Proprietary TranSwitch Corporation Information for use Solely by its Customers
7-0
7-4
3-0
7-1
Bit
0
Add Alarms
Add Alarms
RESETD
Channels
Channels
Symbol
Register
Register
Polling
Polling
24-17
28-25
Polling Registers, Channels 24-17 Alarms: Bit 7 corresponds to the
polling bit for channel 24. A polling bit is set to 1 when one or more A/B
add side latched alarms occurs in a channel and the corresponding
mask bit is set to 1. This bit is cleared when the add side latched alarms
corresponding to the channel that is set to 1 are read, or the mask bit
associated with the alarm in the interrupt hierarchy is set to 0.
Not used:
Polling Registers, Channels 28-25 Alarms: Bit 3 corresponds to the
polling bit for channel 28. A polling bit is set to 1 when one or more A/B
add side latched alarms occurs in a channel and the corresponding
mask bit is set to 1. This bit is cleared when the add side latched alarms
corresponding to the channel that is set to 1 are read, or the mask bit
associated with the alarm in the interrupt hierarchy is set to 0.
Not used:
Reset Sequence Completed: Indication that the hardware reset
(RESET lead) or software reset (control bit RESETH) is completed. It
takes approximately 4 microseconds for this bit to set to a 1 after the
hardware reset or software reset control bit has been invoked. Micropro-
cessor access of the TEMx28 is not valid until this bit is set to 1. This bit
goes to zero immediately after the hardware or software reset has been
invoked.
- 153 of 246 -
DATA SHEET
Description
TXC-04222-MB, Ed. 6
TXC-04222
TEMx28
June 2003

Related parts for TXC-04222-AIOG