TXC-04222-AIOG Transwitch Corporation, TXC-04222-AIOG Datasheet - Page 212

no-image

TXC-04222-AIOG

Manufacturer Part Number
TXC-04222-AIOG
Description
Manufacturer
Transwitch Corporation
Datasheet

Specifications of TXC-04222-AIOG

Screening Level
Industrial
Package Type
BGA
Lead Free Status / Rohs Status
Not Compliant
June 2003
TEMx28
TXC-04222
TXC-04222-MB, Ed. 6
Address
X+118
Bit
7
6
5
4
3
2
1
0
Proprietary TranSwitch Corporation Information for use Solely by its Customers
PAnVCAIS
PAnUNEQ
PAnSLER
PAnRDIC
PAnRDIP
PAnRDIS
Symbol
PAnRFI
Not used:
A Side Drop Bus Channel n VC AIS One Second Alarm Indication:
This bit position is set when the A side VC AIS alarm indication has
changed state in the last one second interval or is 1 at the end of the
interval. This bit is disabled if the one second pulse is not applied. This
indication does not cause an interrupt.
A Side Drop Bus Channel n Unequipped One Second Alarm Indica-
tion: This bit position is set when the A side unequipped alarm indication
has changed state in the last one second interval or is 1 at the end of the
interval. This bit is disabled if the one second pulse is not applied. This
indication does not cause an interrupt.
A Side Drop Bus Channel n Remote Connectivity Defect One Sec-
ond Alarm Indication: This bit position is set when the A side remote
connectivity defect alarm indication has changed state in the last one
second interval or is 1 at the end of the interval. This bit is disabled if the
one second pulse is not applied. This indication does not cause an inter-
rupt.
A Side Drop Bus Channel n Remote Payload Defect One Second
Alarm Indication: This bit position is set when the A side remote pay-
load defect alarm indication has changed state in the last one second
interval or is 1 at the end of the interval. This bit is disabled if the one
second pulse is not applied. This indication does not cause an interrupt.
A Side Drop Bus Channel n Remote Server Defect Indication or Sin-
gle Bit RDI One Second Alarm Indication: This bit position is set when
the A side remote server defect alarm or single bit RDI indication has
changed state in the last one second interval or is 1 at the end of the
interval. This bit is disabled if the one second pulse is not applied. This
indication does not cause an interrupt.
A Side Drop Bus Channel n Signal label Mismatch One Second
Alarm Indication: This bit position is set when the A side signal label
mismatch alarm indication has changed state in the last one second
interval or is 1 at the end of the interval. This bit is disabled if the one
second pulse is not applied. This indication does not cause an interrupt.
A Side Drop Bus Channel n Remote Failure One Second Alarm Indi-
cation: This bit position is set when the A side remote failure indication
has changed state in the last one second interval or is 1 at the end of the
interval. This bit is disabled if the one second pulse is not applied. This
indication does not cause an interrupt.
DATA SHEET
- 212 of 246 -
Description

Related parts for TXC-04222-AIOG