TXC-04222-AIOG Transwitch Corporation, TXC-04222-AIOG Datasheet - Page 175

no-image

TXC-04222-AIOG

Manufacturer Part Number
TXC-04222-AIOG
Description
Manufacturer
Transwitch Corporation
Datasheet

Specifications of TXC-04222-AIOG

Screening Level
Industrial
Package Type
BGA
Lead Free Status / Rohs Status
Not Compliant
Address
085
Proprietary TranSwitch Corporation Information for use Solely by its Customers
7-6
Bit
5
4
3
2
1
0
PB3HOOM B Side Drop Bus H4 Byte Out Of Multiframe Alignment One Second
PB2HOOM B Side Drop Bus H4 Byte Out Of Multiframe Alignment One Second
PB1HOOM B Side Drop Bus H4 Byte Out Of Multiframe Alignment One Second
PB3HLOM
PB2HLOM
PB1HLOM
Symbol
Not used:
Alarm Indication - STS-3 STS-1 No. 3/AU-3 C: This bit position is set
when the B side STS-3 STS-1 No. 3/AU-3 C H4 byte Out Of Multiframe
Alignment alarm indication has changed state in the last one second
interval or is 1 at the end of the interval. This bit is disabled if the one
second pulse is not applied. This indication does not cause an interrupt.
Alarm Indication - STS-3 STS-1 No. 2/AU-3 B: This bit position is set
when the B side STS-3 STS-1 No. 2/AU-3 B H4 byte Out Of Multiframe
Alignment alarm indication has changed state in the last one second
interval or is 1 at the end of the interval. This bit is disabled if the one
second pulse is not applied. This indication does not cause an interrupt.
Alarm Indication - STS-3 STS-1 No. 1/AU-3 A, STM-1 VC-4: This bit
position is set when the B side STS-3 STS-1 No. 1/AU-3 A or the STM-1
VC-4 H4 byte Out Of Multiframe Alignment alarm indication has changed
state in the last one second interval or is 1 at the end of the interval. This
bit is disabled if the one second pulse is not applied. This indication does
not cause an interrupt.
B Side Drop Bus H4 Byte Loss Of Multiframe Alignment One Sec-
ond Alarm Indication - STS-3 STS-1 No. 3/AU-3 C: This bit position is
set when the B side STS-3 STS-1 No. 3/AU-3 C H4 byte Loss Of Multi-
frame Alignment alarm indication has changed state in the last one sec-
ond interval or is 1 at the end of the interval. This bit is disabled if the one
second pulse is not applied. This indication does not cause an interrupt.
B Side Drop Bus H4 Byte Loss Of Multiframe Alignment One Sec-
ond Alarm Indication - STS-1 No. 2/AU-3 B: This bit position is set
when the B side STS-3 /STS-1 No. 2/AU-3 B H4 byte Loss Of Multiframe
Alignment alarm indication has changed state in the last one second
interval or is 1 at the end of the interval. This bit is disabled if the one
second pulse is not applied. This indication does not cause an interrupt.
B Side Drop Bus H4 Byte Loss Of Multiframe Alignment One Sec-
ond Alarm Indication - STS-3 STS-1 No. 1/AU-3 A, STM-1 VC-4: This
bit position is set when the B side STS-3 STS-1 No.1/AU-3 A or the
STM-1 VC-4 H4 byte Loss Of Multiframe Alignment alarm indication has
changed state in the last one second interval or is 1 at the end of the
interval. This bit is disabled if the one second pulse is not applied. This
indication does not cause an interrupt.
- 175 of 246 -