Address
064
Proprietary TranSwitch Corporation Information for use Solely by its Customers
7-5
Bit
4
3
2
1
0
PA3UAIS
PA2UAIS
PA1UAIS
PADLOC
PADPAR
Symbol
Not used:
A Side Drop Bus Upstream AIS One Second Alarm Indication -
STS-3 STS-1 No. 3/AU-3 C: This bit position is set when the A side
received upstream AIS alarm Indication - STS-3 STS-1 No. 3/AU-3 C
has changed state in the last one second interval or is 1 at the end of the
interval. This bit is disabled if the one second pulse is not applied. This
indication does not cause an interrupt.
A Side Drop Bus Upstream AIS One Second Alarm Indication -
STS-3 STS-1 No. 2/AU-3 B: This bit position is set when the A side
received upstream AIS alarm Indication - STS-3 STS-1 No. 2/AU-3 B
has changed state in the last one second interval or is 1 at the end of the
interval. This bit is disabled if the one second pulse is not applied. This
indication does not cause an interrupt.
A Side Drop Bus Upstream AIS One Second Alarm Indication -
STS-1 No. 1/AU-3 A and STM-1 VC-4: This bit position is set when the
A side received upstream AIS alarm Indication - STS-3 STS-1 No.
1/AU-3 A or STM-1 VC-4 has changed state in the last one second inter-
val or is 1 at the end of the interval. This bit is disabled if the one second
pulse is not applied. This indication does not cause an interrupt.
A Side Drop Bus Parity One Second Alarm Indication: This bit posi-
tion is set when the A side parity error alarm indication has changed
state in the last one second interval or is 1 at the end of the interval. This
bit is disabled if the one second pulse is not applied. This indication does
not cause an interrupt.
A Side Drop Bus Loss Of Clock One Second Alarm Indication: This
bit position is set when the A side loss of clock alarm indication has
changed state in the last one second interval or is 1 at the end of the
interval. This bit is disabled if the one second pulse is not applied. This
indication does not cause an interrupt.