UPD78F0500AMC-CAB-AX Renesas Electronics America, UPD78F0500AMC-CAB-AX Datasheet - Page 480

no-image

UPD78F0500AMC-CAB-AX

Manufacturer Part Number
UPD78F0500AMC-CAB-AX
Description
MCU 8BIT 30SSOP
Manufacturer
Renesas Electronics America
Series
78K0/Kx2r
Datasheet

Specifications of UPD78F0500AMC-CAB-AX

Core Processor
78K/0
Core Size
8-Bit
Speed
20MHz
Connectivity
3-Wire SIO, I²C, LIN, UART/USART
Peripherals
LVD, POR, PWM, WDT
Number Of I /o
23
Program Memory Size
8KB (8K x 8)
Program Memory Type
FLASH
Ram Size
512 x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 4x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
78K0/Kx2
R01UH0008EJ0401 Rev.4.01
Jul 15, 2010
(f) Reception error
Three types of errors may occur during reception: a parity error, framing error, or overrun error. If the error flag of
asynchronous serial interface reception error status register 6 (ASIS6) is set as a result of data reception, a
reception error interrupt request (INTSR6/INTSRE6) is generated.
Which error has occurred during reception can be identified by reading the contents of ASIS6 in the reception
error interrupt (INTSR6/INTSRE6) servicing (see Figure 15-6).
The contents of ASIS6 are cleared to 0 when ASIS6 is read.
The reception error interrupt can be separated into reception completion interrupt (INTSR6) and error interrupt
(INTSRE6) by clearing bit 0 (ISRM6) of asynchronous serial interface operation mode register 6 (ASIM6) to 0.
1. If ISRM6 is cleared to 0 (reception completion interrupt (INTSR6) and error interrupt (INTSRE6) are
2. If ISRM6 is set to 1 (error interrupt is included in INTSR6)
INTSRE6
INTSRE6
Parity error
Framing error
Overrun error
INTSR6
INTSR6
separated)
(a) No error during reception
(a) No error during reception
Reception Error
The parity specified for transmission does not match the parity of the receive data.
Stop bit is not detected.
Reception of the next data is completed before data is read from receive buffer
register 6 (RXB6).
Figure 15-20. Reception Error Interrupt
Table 15-3. Cause of Reception Error
INTSRE6
INTSRE6
INTSR6
INTSR6
CHAPTER 15 SERIAL INTERFACE UART6
Cause
(b) Error during reception
(b) Error during reception
480