XW2Z-070T-1 Omron, XW2Z-070T-1 Datasheet - Page 111

no-image

XW2Z-070T-1

Manufacturer Part Number
XW2Z-070T-1
Description
Special Nissan
Manufacturer
Omron
Series
XW2Zr
Type
DB09r
Datasheet

Specifications of XW2Z-070T-1

1st Connector
Plug, Male Pins
2nd Connector
Plug, Male Pins
Number Of Positions
9
Length
2.3' (701.0mm)
Color
Beige, Individual (Round)
Usage
Communication
Contact Finish
Gold
Contact Finish Thickness
15µin (0.38µm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Shielding
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z070T1
Remote I/O Communications
DM 6605
DM 6606
DM 6607
DM 6608
DM 6609
Word
00 to 03 DeviceNet Read/Write area setting
04 to 07 Transmission of CPM2B-S status to the DeviceNet Master
08 to 15 Not used.
00 to 07 DeviceNet I/O Link Write
08 to 15
00 to 15
00 to 07 DeviceNet I/O Link Read
08 to 15
00 to 15
Bits
0 (Hex): Read (IN) IR 020 to IR 027; Write (OUT) IR 030 to IR 037
1 (Hex): Use settings in DM 6606 to DM 6609.
0 (Hex): Attach status information ahead of data.
1 (Hex): Do not attach status information ahead of data.
(OUT) area settings
(Master → CPM2B-S)
(IN) area settings
(CPM2B-S → Master)
Note
1. A system failure error (PC Setup setting error) will occur if the number of
2. Data written through DeviceNet is valid even if the PC is in PROGRAM
3. If words in any areas other than the IR area (IR 000 to IR 227) or LR area
bytes is set to 00 (Hex) for both the write and read areas.
mode, so outputs may go ON when the PC is in PROGRAM mode if output
bits are allocated to the DeviceNet I/O Link Write area. To prevent outputs
from going ON while the PC is in PROGRAM mode, do not allocate output
bits directly to the DeviceNet I/O Link Write area.
(LR 00 to LR 15) are allocated to the I/O Link Read area, the data may not
be cleared even when the power is interrupted, possibly causing data from
immediately before power interruption to be read by the master. If this cre-
ates a potential problem, use the following measures to eliminate the prob-
lem.
When a fatal error occurs at a slave, the master may read data from imme-
diately before the error. In this case also, monitor the status at the master
and do not read the data.
• When starting in RUN or MONITOR mode, configure the ladder pro-
• When starting in PROGRAM mode, it will not be possible to take direct
gram so that the Read area is rewritten with appropriate data.
measures at the slave. Monitor the status at the master and do not
read the data when the operating mode is PROGRAM mode.
Number of bytes (see note 1)
Data area
01 (Hex):
02 (Hex):
03 (Hex):
04 (Hex):
05 (Hex):
07 (Hex):
Number of bytes (see note 1)
01 to 40 (Hex) (equivalent to 0 to 64 decimal)
Starting word address
0000 to 07FF (Hex) (equivalent to 0000 to 2047 decimal)
Data area
01 (Hex):
02 (Hex):
03 (Hex):
04 (Hex):
05 (Hex):
06 (Hex):
07 (Hex):
01 to 40 (Hex) (equivalent to 0 to 64 decimal)
Starting word address
0000 to 07FF (Hex) (equivalent to 0000 to 2047 decimal)
Function
I/O area 1 (IR 000 to IR 049)
I/O area 2 (IR 200 to IR 227)
DM area (DM 0000 to DM 2047)
LR area (LR 00 to LR 15)
HR area (HR 00 to HR 19)
Timer/counter area (TC 000 to TC 255)
I/O area 1 (IR 000 to IR 049)
I/O area 2 (IR 200 to IR 227)
DM area (DM 0000 to DM 2047)
LR area (LR 00 to LR 15)
HR area (HR 00 to HR 19)
AR area (AR 00 to AR 23)
Timer/counter area (TC 000 to TC 255)
Section 7-2
0 (Hex)
0 (Hex)
0 (Hex)
00 (Hex)
00 (Hex)
0000 (Hex)
00 (Hex)
00 (Hex)
0000 (Hex)
Default
99