XW2Z-070T-1 Omron, XW2Z-070T-1 Datasheet - Page 130

no-image

XW2Z-070T-1

Manufacturer Part Number
XW2Z-070T-1
Description
Special Nissan
Manufacturer
Omron
Series
XW2Zr
Type
DB09r
Datasheet

Specifications of XW2Z-070T-1

1st Connector
Plug, Male Pins
2nd Connector
Plug, Male Pins
Number Of Positions
9
Length
2.3' (701.0mm)
Color
Beige, Individual (Round)
Usage
Communication
Contact Finish
Gold
Contact Finish Thickness
15µin (0.38µm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Shielding
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z070T1
Cycle Time
Overseeing
Wait for completion
of CompoBus/S
communications
CompoBus/S input
refreshing
Program execution
Cycle time
calculation
CompoBus/S output
refreshing
I/O output refreshing Write output data (results of executing program)
I/O input refreshing
DeviceNet I/O
refreshing
RS-232C port ser-
vicing
Peripheral port ser-
vicing
DeviceNet communi-
cations servicing
Process
Set cycle watchdog timer, check I/O bus, check
UM, refresh clock, refresh bits allocated to new
functions.
Wait for completion of the CompoBus/S commu-
nications started in the CompoBus/S output
refreshing process.
Read input data from CompoBus/S Master
ASIC.
Execute user program.
Wait until minimum cycle time has elapsed if a
minimum cycle time is set in DM 6619 of PC
Setup.
Calculate of cycle time.
Write output data to CompoBus/S Master ASIC.
Start CompoBus/S communications.
to output bits.
Read input data from input bits.
Write output data to DeviceNet interface and
read input data.
Communications processing when a Program-
ming Device or Communications Adapter is con-
nected to the RS-232C port.
Service device connected to peripheral port
when a Programming Device or Adapter is con-
nected.
Perform communications processing (explicit
message communications) with the DeviceNet
Master.
Note
2. The maximum cycle time and current cycle time are stored in AR 14 and
3. The cycle time varies with the processing required and so it is possible that
1. The CPM2B-S starts I/O refreshing after CompoBus/S communications
2. Even if the CompoBus/S is not used, the cycle time will never be shorter
3. The cycle time will be affected if there is a connection to a DeviceNet net-
AR 15 respectively.
the calculated value and the actual value may not be the same.
are completed. If the cycle time is shorter than the CompoBus/S commu-
nications response time, the CPU will wait until CompoBus/S communica-
tions are completed before starting I/O refreshing again. In effect, this
delay results in a minimum cycle time equivalent to the CompoBus/S com-
munications response time.
than the CompoBus/S communications response time.
work (-DRT models only). Adjust the system while connected to the De-
viceNet network.
Content
0.3 ms
---
0.02 ms
Total time for executing instructions. (Varies
according to content of user’s program.)
Negligible except for the delay itself when
required.
0.05 ms
CPM2B-S CPU Unit:0.06 ms
Expansion I/O Unit:0.3 ms
0.1 ms
0.55 ms min., 5% or less of cycle time up to
131 ms
(The percentage of cycle time allocated to
RS-232C servicing can be set in DM 6616.)
0.55 ms min., 5% or less of cycle time up to
131 ms
(The percentage of cycle time allocated to
peripheral port servicing can be set in DM
6617.)
65.536 ms max.
Time requirements
Section 8-1
119