Basic PC Operation and I/O Processes
4-7-9
Error Detection and Error Log Settings
Note Low battery detection is enabled only when the low battery detection switch is
Input Time Constants for IR 000
Input Time Constants for IR 003 to IR 005
The nine possible settings for the input time constant are shown below. (Set
only the rightmost digit for each setting for IR 000.)
00 (Hex): 8 ms 01 (Hex): 1 ms 02 (Hex): 2 ms
03 (Hex): 4 ms 04 (Hex): 8 ms 05 (Hex): 16 ms
06 (Hex): 32 ms 07 (Hex): 64 ms08 (Hex): 128 ms
Error Detection and Error Log Operation (DM 6655)
Make the settings shown below to determine whether or not a non-fatal error
is to be generated when the cycle time exceeds 100 ms or when the voltage
of the built-in battery drops, and to set the method for storing records in the
error log when errors occur.
Battery errors and cycle time overrun errors are non-fatal errors.
Refer to 4-8 Error Log below for details on the error log.
ON. (See page 31.)
Low battery voltage detection (See note.)
Cycle time over detection
Error log storage method
0 (Hex): Detect
1 (Hex): Don't detect
0 (Hex): Detect
1 (Hex): Don't detect
0 (Hex): Error records for the 7 most recent errors always stored (older errors de-
leted).
1 (Hex): Only the first 7 error records stored (no errors stored beyond that point).
2 to F (Hex): Error records not stored.
Default: Low battery voltage and cycle time over errors detected, and error records
stored for the 7 most recent errors.
Time constant for IR 00003 to IR 00004 (1 digit BCD; see below.)
Time constant for IR 00000 to IR 00002 (1 digit BCD; see below.)
Default: 0000 (8 ms for each)
DM 6622: IR 003 and IR 004
DM 6623: IR 005
Time constant for IR 00005 (1 digit BCD; see below.)
Time constant for IR 004
Time constant for IR 003 and IR 005
Default: 0000 (8 ms for each)
DM 6622 to DM 6623
DM6655
Bit
15
DM 6620
Not used.
Bit
Bit
Always
0
15
15
0
0
Section 4-7