XW2Z-070T-1 Omron, XW2Z-070T-1 Datasheet - Page 17

no-image

XW2Z-070T-1

Manufacturer Part Number
XW2Z-070T-1
Description
Special Nissan
Manufacturer
Omron
Series
XW2Zr
Type
DB09r
Datasheet

Specifications of XW2Z-070T-1

1st Connector
Plug, Male Pins
2nd Connector
Plug, Male Pins
Number Of Positions
9
Length
2.3' (701.0mm)
Color
Beige, Individual (Round)
Usage
Communication
Contact Finish
Gold
Contact Finish Thickness
15µin (0.38µm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Shielding
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z070T1
Built-in Motor Control Capability
Synchronized Pulse
Control
High-speed Counters and
Interrupts
Easy Position Control with
Pulse Outputs
High-speed Input Capabilities for Machine Control
High-speed Interrupt Input
Function
Quick-response Input
Function
Stabilizing Input Filter
Function
Other Functions
Interval Timer Interrupts
Analog Settings
Long-term Timer
4
CPM2B-S Features and Functions
Synchronized pulse control provides an easy way to synchronize the opera-
tion of a peripheral piece of equipment with the main equipment. The output
pulse frequency can be controlled as some multiple of the input pulse fre-
quency, allowing the speed of a peripheral piece of equipment (such as a sup-
ply conveyor) to be synchronized with the speed of the main piece of
equipment.
The CPM2B-S has a total of five high-speed counter inputs. The one high-
speed counter input has a response frequency of 20 kHz/5 kHz and the four
interrupt inputs in counter mode have a response frequency of 2 kHz.
The high-speed counter can be used in any one of the four input modes: dif-
ferential phase mode (5 kHz), pulse plus direction input mode (20 kHz), up/
down pulse mode (20 kHz), or increment mode (20 kHz). Interrupts can be
triggered when the count matches a set value or falls within a specified range.
The interrupt inputs in counter mode can be used for incrementing counters or
decrementing counters (2 kHz) and trigger an interrupt (executing the inter-
rupt program) when the count matches the target value.
CPM2B-S PCs have two outputs that can produce 10 Hz to 10 kHz pulses
(single-phase outputs).
When used as single-phase pulse outputs, there can be two outputs with a
frequency range of 10 Hz to 10 kHz with a fixed duty ratio or 0.1 to 999.9 Hz
with a variable duty ratio (0 to 100% duty ratio).
When used as pulse plus direction or up/down pulse outputs, there can be
just one output with a frequency range of 10 Hz to 10 kHz.
There are four inputs used for interrupt inputs (shared with quick-response
inputs and interrupt inputs in counter mode) with a minimum input signal width
of 50 µs and response time of 0.3 ms. When an interrupt input goes ON, the
main program is stopped and the interrupt program is executed.
There are four inputs used for quick-response inputs (shared with interrupt
inputs and interrupt inputs in counter mode) that can reliably read input sig-
nals with a signal width as short as 50 µs.
The input time constant for all inputs can be set to 1 ms, 2 ms, 3 ms, 5 ms,
10 ms, 20 ms, 40 ms, or 80 ms. The effects of chattering and external noise
can be reduced by increasing the input time constant.
The interval timer can be set between 0.5 and 319,968 ms and can be set to
generate just one interrupt (one-shot mode) or periodic interrupts (scheduled
interrupt mode).
There are two controls on the CPU Board that can be turned to change the
analog settings (0 to 200 BCD) in IR 250 and IR 251. These controls can be
used to easily change or fine-tune machine settings such as a conveyor belt’s
pause time or feed rate.
TIML(–) is a long-term timer that accommodates set values up to 99,990 sec-
onds (27 hours, 46 minutes, 30 seconds). When combined with the SEC-
ONDS TO HOURS conversion instruction (HMS(–)), the long-term timer
provides an easy way to control equipment scheduling.
Encoder
Pulses are output as a fixed multiple of the input frequency.
CPM2B-S
Motor driver Motor
Section 1-1

Related parts for XW2Z-070T-1