XW2Z-070T-1 Omron, XW2Z-070T-1 Datasheet - Page 78

no-image

XW2Z-070T-1

Manufacturer Part Number
XW2Z-070T-1
Description
Special Nissan
Manufacturer
Omron
Series
XW2Zr
Type
DB09r
Datasheet

Specifications of XW2Z-070T-1

1st Connector
Plug, Male Pins
2nd Connector
Plug, Male Pins
Number Of Positions
9
Length
2.3' (701.0mm)
Color
Beige, Individual (Round)
Usage
Communication
Contact Finish
Gold
Contact Finish Thickness
15µin (0.38µm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Shielding
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z070T1
4-4
These bits mainly serve as flags related to CPM2B-S operation or contain present and set values for various
functions. The functions of the SR area are explained in the following table.
66
SR Area
SR 228,
SR 229
SR 230,
SR 231
SR 232
to
SR 235
SR 236
to
SR 239
SR 240
SR 241
SR 242,
SR 243
SR 244
SR 245
SR 246,
SR 247
SR 248,
SR 249
SR 250,
SR 251
Word(s)
SR Area
00 to 15
00 to 15
00 to 15
00 to 15
00 to 15
00 to 15
00 to 15
00 to 15
00 to 15
00 to 15
00 to 15
00 to 15
Bit(s)
Pulse Output PV 0
Contains the pulse output PV (–16,777,215 to 16,777,215). SR 22915 acts as the sign
bit; a negative number is indicated when SR 22915 is ON.
(The same PV data can be read immediately with PRV(62).)
Only Pulse Output PV 0 is used for ACC(– –).
Pulse Output PV 1
Contains the pulse output PV (–16,777,215 to 16,777,215). SR 23115 acts as the sign
bit; a negative number is indicated when SR 23115 is ON.
(The same PV data can be read immediately with PRV(62).)
Macro Function Input Area
Contains the input operands for MCRO(99).
(Can be used as work bits when MCRO(99) is not used.)
Macro Function Output Area
Contains the output operands for MCRO(99).
(Can be used as work bits when MCRO(99) is not used.)
Interrupt Input 00003 Counter Mode SV
SV when interrupt input 00003 is used in counter mode (4 digits hexadecimal).
(Can be used as work bits when interrupt input 00003 is not used in counter mode.)
Interrupt Input 00004 Counter Mode SV
SV when interrupt input 00004 is used in counter mode (4 digits hexadecimal).
(Can be used as work bits when interrupt input 00004 is not used in counter mode.)
Not used.
Interrupt Input 00003 Counter Mode PV
Counter PV when interrupt input 00003 is used in counter mode (4 digits hexadecimal).
Interrupt Input 00004 Counter Mode PV
Counter PV when interrupt input 00004 is used in counter mode (4 digits hexadecimal).
Not used.
High-speed Counter PV Area
(Can be used as work bits when the high-speed counter is not used.)
Not used.
Note “Read-only” words and bits can be read as status in controller PC operation,
but they cannot be written from the ladder program. Bits and words that are
“Not used” are also read-only.
Function
Section 4-4
Read-
only
Read/
write
Read-
only
Read-
only
Read/
write