XW2Z-070T-1 Omron, XW2Z-070T-1 Datasheet - Page 63

no-image

XW2Z-070T-1

Manufacturer Part Number
XW2Z-070T-1
Description
Special Nissan
Manufacturer
Omron
Series
XW2Zr
Type
DB09r
Datasheet

Specifications of XW2Z-070T-1

1st Connector
Plug, Male Pins
2nd Connector
Plug, Male Pins
Number Of Positions
9
Length
2.3' (701.0mm)
Color
Beige, Individual (Round)
Usage
Communication
Contact Finish
Gold
Contact Finish Thickness
15µin (0.38µm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Shielding
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z070T1
Wiring and Connections
3-5-3
Wiring CompoBus/S Transmission Lines
1,2,3...
Note When VCTF cable is being used, cover the end of the cable sheathing with
The diode should satisfy the following requirements:
Inrush Current Considerations
When a relay or transistor output is used to switch a load with a high inrush
current such as an incandescent lamp, suppress the inrush current as shown
below.
Fuse Insertion
The CPM2B-S with transistor output may burn if the load is short-circuited,
therefore, insert a protective fuse in series with the load.
Use special flat cable or VCTF cable for the transmission lines that connect
the nodes in the CompoBus/S I/O Link. (Special flat cables and VCTF cables
cannot be combined in the same system.)
Use the following procedure to wire the CompoBus/S communications cables.
1. Strip off the length of wire insulation recommended for the crimp connec-
electrical tape or heat-shrink tubing as shown in the following diagram.
2. Crimp pin terminals on the stripped ends of the communications cable and
Flat cable
VCTF cable
Peak reverse-breakdown voltage must be at least 3 times the load voltage.
Average rectified current must be 1 A.
tors being used and tightly twist the bare wire strands together.
secure the terminal and wire with electrical tape or heat-shrink tubing.
Note a) We recommend the following pin terminals.
Name
Countermeasure 1
OUT
COM
Providing a dark current of
approx. one-third of the rated
value through an incandescent
lamp
XB1T-W10
---
R
Model number
Secure the cable sheathing with
electrical tape or heat-shrink tubing.
Weidmüller
046290 Sleeve
4-core flat cable, 0.75 mm
2-core VCTF, 0.75 × 20
OUT
COM
Signal wire
Countermeasure 2
Providing a limiting resistor
Specifications
R
2
Section 3-5
51

Related parts for XW2Z-070T-1