XW2Z-070T-1 Omron, XW2Z-070T-1 Datasheet - Page 162

no-image

XW2Z-070T-1

Manufacturer Part Number
XW2Z-070T-1
Description
Special Nissan
Manufacturer
Omron
Series
XW2Zr
Type
DB09r
Datasheet

Specifications of XW2Z-070T-1

1st Connector
Plug, Male Pins
2nd Connector
Plug, Male Pins
Number Of Positions
9
Length
2.3' (701.0mm)
Color
Beige, Individual (Round)
Usage
Communication
Contact Finish
Gold
Contact Finish Thickness
15µin (0.38µm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Shielding
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z070T1
Maintenance Inspections
9-5
Inspection Items
Required Tools
9-6
Power supply
Environmental
conditions
I/O power supply
Installation status
Product service life
Inspection items
Maintenance Inspections
Battery Replacement
! W A R N I N G
Determine whether the voltage fluctuation
at the power supply terminals is within
specifications.
Is the ambient temperature inside the panel
appropriate?
Is the ambient humidity inside the panel
appropriate?
Has dirt or dust collected?
Is the voltage fluctuation measured at the
I/O terminals within the standard range?
Are all Boards securely installed?
Are all connection cables and connectors
inserted completely and locked?
Are any of the external wiring screws loose? Nothing is loose
Are any of the external wiring cables
frayed?
Contact output relay
Battery (C500-BAT08)
Note Do not attempt to disassemble, repair, or modify the PC in any way.
In order for your SYSMAC system to operate in optimum condition, be sure to
carry out daily or periodical inspections.
The main system components of a SYSMAC system are semiconductors, and
it contains few components with limited lifetimes. Poor environmental condi-
tions, however, can lead to deterioration of the electrical components, making
regular maintenance necessary.
The standard period for maintenance checks is 6 months to 1 year, but more
frequent checks are required if the PC is operated in more demanding condi-
tions.
If the criteria are not met, adjust to within the specified ranges.
Standard Tools (Required)
Measurement Devices (May be Needed)
Do not drop, disassemble, crush, short-circuit, recharge, or dispose of the bat-
tery in fire. The battery may explode, burn, or leak and cause personal injury.
• Screwdrivers (Phillips and flat-blade)
• Voltage tester or digital voltage meter
• Industrial alcohol and a cotton cloth
• Synchroscope
• Cathode-ray oscilloscope
• Thermometer, hygrometer
Details
Within the voltage variation
range (20.4 to 26.4 VDC)
0 to 55°C
35% to 85% RH with no
condensation
None
Each I/O terminal must
conform to the specifications
Nothing is loose
Nothing is loose
No external abnormalities
Electrical:
Mechanical:
5 years (at 25°C)
Resistance load:
300,000 operations
Inductive load:
100,000 operations
10,000,000 operations
Criteria
Tester
Thermometer
Hygrometer
Visual inspection
Tester
Phillips screwdriver
Visual inspection
Phillips screwdriver
Visual inspection
---
---
Remarks
Section 9-5
151