User’s Manual
Hardware Description
0010 = RMFB: Receive Multiframe Begin (Output)
0011 = RSIGM: Receive Signaling Marker (Output)
0100 = RSIG: Receive Signaling Data (Output)
0101 = DLR: Data Link Bit Receive (Output)
0110 = FREEZE: Freeze Signaling (Output)
0111 = RFSP: Receive Frame Synchronous Pulse (Output)
1001 = GPI: General Purpose Input
1010 = GPOH: General Purpose Output High
1011 = GPOL: General Purpose Output Low
1100 = LOS: Loss of Signal Output (status of FRS0.LOS)
Transmit multifunction Port Configuration
The multifunction ports XP(A to D) are bidirectional. After Reset these
ports are configured as inputs. With the selection of the pin function
the In/Output configuration is also achieved. Each of the four different
input functions (SYPX, XMFS, XSIG, TCLK) may only be selected
once. No input function must be selected twice or more. SYPX and
position of the current frame. Programming of the bit position is
done by using registers RC(1:0). The internal time slot assigner
is disabled. The RFM offset calculation formula has to be used.
CMR2.IRSP = 1:
Internally generated frame synchronization pulse sourced by
the DCO-R circuitry. The pulse is active low for one 1.544 MHz
period.
Marks the beginning of every received multiframe or
optionally the begin of every CAS multiframe begin (active
high).
Marks the time slots which are defined by register RTR(4:1)
of every frame on port RDO.
The received CAS multiframe is transmitted on this pin. Time
slot on RSIG correlates directly to the time slot assignment on
RDO.
Marks the S
The freeze signaling status is active high by detecting a
Loss-of-signal alarm, or a Loss of CAS Frame Alignment or a
receive slip (positive or negative). It stays high for at least one
complete multiframe after the alarm disappears. Setting
SIC2.FFS enforces a high on pin FREEZE.
Marks the frame begin in the receivers synchronous state.
This marker is active low for 648 ns with a frequency of 8 kHz.
a
-bits within the data stream on RDO.
403
DS1.1, 2003-10-23
T1/J1 Registers
PEF 2256 H/E
FALC
®
56