AT91SAM9G45-CU-999 Atmel, AT91SAM9G45-CU-999 Datasheet - Page 1035

IC MCU ARM9 APMC 324TFBGA

AT91SAM9G45-CU-999

Manufacturer Part Number
AT91SAM9G45-CU-999
Description
IC MCU ARM9 APMC 324TFBGA
Manufacturer
Atmel
Series
AT91SAMr
Datasheet

Specifications of AT91SAM9G45-CU-999

Core Processor
ARM9
Core Size
16/32-Bit
Speed
400MHz
Connectivity
EBI/EMI, Ethernet, I²C, IrDA, MMC, SPI, SSC, UART/USART, USB
Peripherals
AC'97, DMA, I²S, LCD, POR, PWM, WDT
Number Of I /o
160
Program Memory Size
64KB (64K x 8)
Program Memory Type
ROM
Ram Size
128K x 8
Voltage - Supply (vcc/vdd)
0.9 V ~ 1.1 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
324-TFBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
Supplier Unconfirmed

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM9G45-CU-999
Manufacturer:
Atmel
Quantity:
10 000
42.6.3
42.6.3.1
42.6.3.2
42.6.3.3
6438F–ATARM–21-Jun-10
PWM Controller Operations
Initialization
Changing the Duty Cycle or the Period
Source Clock Selection Criteria
Before enabling the output channel, this channel must have been configured by the software
application:
It is possible to synchronize different channels by enabling them at the same time by means of
writing simultaneously several CHIDx bits in the PWM_ENA register.
The large number of source clocks can make selection difficult. The relationship between the
value in the Period Register (PWM_CPRDx) and the Duty Cycle Register (PWM_CDTYx) can
help the user in choosing. The event number written in the Period Register gives the PWM accu-
racy. The Duty Cycle quantum cannot be lower than 1/PWM_CPRDx value. The higher the value
of PWM_CPRDx, the greater the PWM accuracy.
For example, if the user sets 15 (in decimal) in PWM_CPRDx, the user is able to set a value
between 1 up to 14 in PWM_CDTYx Register. The resulting duty cycle quantum cannot be lower
than 1/15 of the PWM period.
It is possible to modulate the output waveform duty cycle or period.
To prevent unexpected output waveform, the user must use the update register (PWM_CUPDx)
to change waveform parameters while the channel is still enabled. The user can write a new
period value or duty cycle value in the update register (PWM_CUPDx). This register holds the
new value until the end of the current cycle and updates the value for the next cycle. Depending
on the CPD field in the PWM_CMRx register, PWM_CUPDx either updates PWM_CPRDx or
PWM_CDTYx. Note that even if the update register is used, the period must not be smaller than
the duty cycle.
• Configuration of the clock generator if DIVA and DIVB are required
• Selection of the clock for each channel (CPRE field in the PWM_CMRx register)
• Configuration of the waveform alignment for each channel (CALG field in the PWM_CMRx
• Configuration of the period for each channel (CPRD in the PWM_CPRDx register). Writing in
• Configuration of the duty cycle for each channel (CDTY in the PWM_CDTYx register).
• Configuration of the output waveform polarity for each channel (CPOL in the PWM_CMRx
• Enable Interrupts (Writing CHIDx in the PWM_IER register)
• Enable the PWM channel (Writing CHIDx in the PWM_ENA register)
• In such a situation, all channels may have the same clock selector configuration and the
register)
PWM_CPRDx Register is possible while the channel is disabled. After validation of the
channel, the user must use PWM_CUPDx Register to update PWM_CPRDx as explained
below.
Writing in PWM_CDTYx Register is possible while the channel is disabled. After validation of
the channel, the user must use PWM_CUPDx Register to update PWM_CDTYx as explained
below.
register)
same period specified.
AT91SAM9G45
1035