EP2AGX190FF35C6N Altera, EP2AGX190FF35C6N Datasheet - Page 78

no-image

EP2AGX190FF35C6N

Manufacturer Part Number
EP2AGX190FF35C6N
Description
IC ARRIA II GX 190K 1152FBGA
Manufacturer
Altera
Series
Arria II GXr

Specifications of EP2AGX190FF35C6N

Number Of Logic Elements/cells
181165
Number Of Labs/clbs
7612
Total Ram Bits
9939
Number Of I /o
612
Voltage - Supply
0.87 V ~ 0.93 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
1152-FBGA
Family Name
Arria® II GX
Number Of Logic Blocks/elements
190300
# I/os (max)
612
Frequency (max)
400MHz
Operating Supply Voltage (typ)
900mV
Logic Cells
190300
Ram Bits
10380902.4
Operating Supply Voltage (min)
0.87V
Operating Supply Voltage (max)
0.93V
Operating Temp Range
0C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
1152
Package Type
FC-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP2AGX190FF35C6N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2AGX190FF35C6N
Manufacturer:
ALTERA
0
Part Number:
EP2AGX190FF35C6N
0
4–6
Figure 4–4. Output Cascading Feature for FIR Structures
Arria II Device Handbook Volume 1: Device Interfaces and Integration
Input
Data
Half-DSP Block
144
The combination of a fast, low-latency four-multiplier adder unit and the “chained
cascade” capability of the output chaining adder provides the optimal FIR and vector
multiplication capability.
To support single-channel type FIR filters efficiently, you can configure one of the
multiplier input registers to form a tap delay line input, saving resources and
providing higher system performance.
Figure 4–4
of commonly found arithmetic rounding and saturation functions in signal
processing.
In addition to the independent multipliers and sum modes, you can use DSP blocks to
perform shift operations. DSP blocks can dynamically switch between logical shift
left/right, arithmetic shift left/right, and rotation operation in one clock cycle.
shows the optional rounding and saturation unit. This unit provides a set
From Previous Half-DSP Block
To Next
Half-DSP Block
44
44
Chapter 4: DSP Blocks in Arria II Devices
December 2010 Altera Corporation
Simplified DSP Operation
44
Result[]