PM7311 pmc-sierra, PM7311 Datasheet - Page 163

no-image

PM7311

Manufacturer Part Number
PM7311
Description
Freedm 84a1024l Assp Telecom Standard Datasheet
Manufacturer
pmc-sierra
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
PM7311-BI
Quantity:
46
Proprietary and Confidential to PMC-Sierra, Inc., and for its customers’ internal use.
Document No.: PMC-2021832, Issue 2
Register 0x40C: TCAS Indirect Channel Provision RAM Timeslot and Control Select
This register provides the link timeslot number and control bits used to access the TCAS channel
provision RAM. Writing to this register triggers an indirect register access.
TSLOT[4:0]
RWB
BUSY
The indirect timeslot number bits (TSLOT[4:0]) indicate the timeslot to be configured or
interrogated in the indirect access. For a channelized T1/J1 link, timeslots 0 to 23 are valid.
For a channelized E1 link, timeslots 0 to 31 are valid. For unchannelized links, only timeslot
0 is valid.
The indirect access control bit (RWB) selects between a configure (write) or interrogate
(read) access to the TCAS channel provision RAM. The address to the TCAS channel
provision RAM is constructed by combining the TSLOT[4:0] and LINK[9:0] bits. Writing a
logic zero to RWB triggers an indirect write operation. Data to be written is taken from the
PROV, and the CHAN[9:0] bits of the TCAS Indirect Channel Data register. Writing a logic
one to RWB triggers an indirect read operation. Addressing of the RAM is the same as in an
indirect write operation. The data read can be found in the PROV, and the CHAN[9:0] bits of
the TCAS Indirect Channel Data register.
The indirect access status bit (BUSY) reports the progress of an indirect access. BUSY is set
high when this register is written, to trigger an indirect access, and will stay high until the
access is complete. At which point, BUSY will be set low. This register should be polled to
determine when data from an indirect read operation is available in the Indirect Data register
or to determine when a new indirect write operation may commence.
Bit
Bit 31
To
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Type
R
R/W
R/W
R/W
R/W
R/W
R/W
FREEDM 84A1024L ASSP Telecom Standard Product Data Sheet
Function
Unused
BUSY
RWB
TSLOT[4]
TSLOT[3]
TSLOT[2]
TSLOT[1]
TSLOT[0]
Default
X
0
0
0
0
0
0
0
Released
163