HD6417144 RENESAS [Renesas Technology Corp], HD6417144 Datasheet - Page 593

no-image

HD6417144

Manufacturer Part Number
HD6417144
Description
32-Bit RISC Microcomputer SuperHTM RISC engine Family/SH7144 Series
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417144F50V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6417144FW50V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
15.4
The A/D converter operates by successive approximation with 10-bit resolution. It has two
operating modes; single mode and scan mode. There are two kinds of scan mode: continuous
mode and single-cycle mode. When changing the operating mode or analog input channel, in order
to prevent incorrect operation, first clear the ADST bit to 0 in ADCR. The ADST bit can be set at
the same time when the operating mode or analog input channel is changed.
15.4.1
In single mode, A/D conversion is to be performed only once on the specified single channel. The
operations are as follows.
1. A/D conversion is started when the ADST bit in ADCR is set to 1, according to software,
2. When A/D conversion is completed, the result is transferred to the A/D data register
3. On completion of conversion, the ADF bit in ADCSR is set to 1. If the ADIE bit is set to 1 at
4. The ADST bit remains set to 1 during A/D conversion. When A/D conversion ends, the ADST
15.4.2
In continuous scan mode, A/D conversion is to be performed sequentially on the specified
channels. The operations are as follows.
1. When the ADST bit in ADCR is set to 1 by software, MTU, or external trigger input, A/D
2. When A/D conversion for each channel is completed, the result is sequentially transferred to
3. When conversion of all the selected channels is completed, the ADF bit in ADCSR is set to 1.
4. Steps 2 to 3 are repeated as long as the ADST bit remains set to 1. When the ADST bit is
MTU, or external trigger input.
corresponding to the channel.
this time, an ADI interrupt request is generated.
bit is automatically cleared to 0 and the A/D converter enters the idle state.
conversion starts on the channel with the lowest number in the group (AN0, AN1, ..., AN3).
the A/D data register corresponding to each channel.
If the ADIE bit is set to 1 at this time, an ADI interrupt is requested after A/D conversion ends.
Conversion of the first channel in the group starts again.
cleared to 0, A/D conversion stops and the A/D converter enters the idle state.
Operation
Single Mode
Continuous Scan Mode
Rev.4.00 Mar. 27, 2008 Page 549 of 882
15. A/D Converter
REJ09B0108-0400