AT91CAP7E-NA-ZJ Atmel, AT91CAP7E-NA-ZJ Datasheet - Page 349

MCU CAP7 FPGA 225LFBGA

AT91CAP7E-NA-ZJ

Manufacturer Part Number
AT91CAP7E-NA-ZJ
Description
MCU CAP7 FPGA 225LFBGA
Manufacturer
Atmel
Series
CAP™r
Datasheets

Specifications of AT91CAP7E-NA-ZJ

Core Processor
ARM7
Core Size
16/32-Bit
Speed
80MHz
Connectivity
EBI/EMI, FPGA, IrDA, SPI, UART/USART, USB
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
32
Program Memory Size
256KB (256K x 8)
Program Memory Type
ROM
Ram Size
160K x 8
Voltage - Supply (vcc/vdd)
1.08 V ~ 1.32 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
225-LFBGA
Processor Series
AT91Mx
Core
ARM7TDMI
Data Bus Width
32 bit
3rd Party Development Tools
JTRACE-ARM-2M, MDK-ARM, RL-ARM, ULINK2
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91CAP7E-NA-ZJ
Manufacturer:
Atmel
Quantity:
10 000
Table 29-2.
29.6.1.2
8549A–CAP–10/08
Source Clock
12 000 000
12 288 000
14 318 180
14 745 600
18 432 000
24 000 000
24 576 000
25 000 000
32 000 000
32 768 000
33 000 000
40 000 000
50 000 000
3 686 400
4 915 200
5 000 000
7 372 800
8 000 000
MHz
Fractional Baud Rate in Asynchronous Mode
Baud Rate Example (OVER = 0)
Expected Baud
The baud rate is calculated with the following formula:
The baud rate error is calculated with the following formula. It is not recommended to work with
an error higher than 5%.
The Baud Rate generator previously defined is subject to the following limitation: the output fre-
quency changes by only integer multiples of the reference frequency. An approach to this
problem is to integrate a fractional N clock generator that has a high resolution. The generator
architecture is modified to obtain Baud Rate changes by a fraction of the reference source clock.
This fractional part is programmed with the FP field in the Baud Rate Generator Register
(US_BRGR). If FP is not 0, the fractional part is activated. The resolution is one eighth of the
clock divider. This feature is only available when using USART normal mode. The fractional
Baud Rate is calculated using the following formula:
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
Rate
Bit/s
BaudRate
Error
=
1
Calculation Result
=
ExpectedBaudRate
-------------------------------------------------- -
MCK
ActualBaudRate
12.00
13.02
19.53
20.00
23.30
24.00
30.00
39.06
40.00
40.69
52.08
53.33
53.71
65.10
81.38
6.00
8.00
8.14
CD
×
16
CD
12
13
20
20
23
24
30
39
40
40
52
53
54
65
81
6
8
8
Actual Baud Rate
38 400.00
38 400.00
39 062.50
38 400.00
38 461.54
37 500.00
38 400.00
38 908.10
38 400.00
38 400.00
38 461.54
38 400.00
38 109.76
38 461.54
38 641.51
38 194.44
38 461.54
38 580.25
Bit/s
AT91CAP7E
0.00%
0.00%
1.70%
0.00%
0.16%
2.40%
0.00%
1.31%
0.00%
0.00%
0.16%
0.00%
0.76%
0.16%
0.63%
0.54%
0.16%
0.47%
Error
349