DF38602RFT10 Renesas Electronics America, DF38602RFT10 Datasheet - Page 334

MCU 3V 16K 32-QFN

DF38602RFT10

Manufacturer Part Number
DF38602RFT10
Description
MCU 3V 16K 32-QFN
Manufacturer
Renesas Electronics America
Series
H8® H8/300H SLPr
Datasheet

Specifications of DF38602RFT10

Core Processor
H8/300H
Core Size
16-Bit
Speed
10MHz
Connectivity
I²C, IrDA, SCI, SSU
Peripherals
POR, PWM, WDT
Number Of I /o
13
Program Memory Size
16KB (16K x 8)
Program Memory Type
FLASH
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 6x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
32-QFN
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Other names
HD64F38602RFT10
HD64F38602RFT10

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF38602RFT10V
Manufacturer:
Renesas Electronics America
Quantity:
135
Section 15 Synchronous Serial Communication Unit (SSU)
Serial Data Reception: Figure 15.7 shows an example of the SSU operation for reception. In
serial reception, the SSU operates as described below.
When the SSU is set as a master device, it outputs a synchronous clock and inputs data. When the
SSU is set as a slave device, it inputs data in synchronized with the input clock. When the SSU is
set as a master device, it outputs a receive clock and starts reception by performing dummy read
on SSRDR.
After eight bits of data is received, the RDRF bit in SSSR is set to 1 and received data is stored in
SSRDR. If the RIE bit in SSER is set to 1 at this time, a RXI is generated. If SSRDR is read, the
RDRF bit is automatically cleared to 0.
When the SSU is set as a master device and reception is ended, received data is read after setting
the RSSTP bit in SSER to 1. Then the SSU outputs eight bits of clocks and operation is stopped.
After that, the RE and RSSTP bits are cleared to 0 and the last received data is read. Note that if
SSRDR is read while the RE bit is set to 1, received clock is output again.
When the eighth clock rises while the RDRF bit is 1, the ORER bit in SSSR is set. Then an
overrun error (OEI) is generated and operation is stopped. When the ORER bit in SSSR is set to 1,
reception cannot be performed. Therefore confirm that the ORER bit is cleared to 0 before
reception.
Figure 15.8 shows a sample flowchart for serial data reception.
Rev. 3.00 May 15, 2007 Page 300 of 516
REJ09B0152-0300
RSSTP
LSI operation
User
processing
SSCK
RDRF
SSO
Dummy read
on SSRDR
Figure 15.7 Example of Operation in Data Reception (MSS = 1)
Bit 0
One frame
RXI generated
Bit 7
Read data in SSRDR
Bit 0
One frame
RXI generated
Bit 7
Set RSSTP to 1
Bit 0
Read data
in SSRDR
RXI generated
Bit 7