M30624FGNGP#D5 Renesas Electronics America, M30624FGNGP#D5 Datasheet - Page 202

IC M16C MCU FLASH 256K 100LQFP

M30624FGNGP#D5

Manufacturer Part Number
M30624FGNGP#D5
Description
IC M16C MCU FLASH 256K 100LQFP
Manufacturer
Renesas Electronics America
Series
M16C™ M16C/60r
Datasheet

Specifications of M30624FGNGP#D5

Core Processor
M16C/60
Core Size
16-Bit
Speed
16MHz
Connectivity
SIO, UART/USART
Peripherals
DMA, PWM, WDT
Number Of I /o
85
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
20K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 18x10b, D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 85°C
Package / Case
100-LQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
M30624FGNGP#D5M30624FGNGP
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Company:
Part Number:
M30624FGNGP#D5M30624FGNGP U3
Manufacturer:
RENESAS
Quantity:
1 000
Company:
Part Number:
M30624FGNGP#D5
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
M30624FGNGP#D5M30624FGNGP#U5
Manufacturer:
Renesas Electronics America
Quantity:
10 000
CPU Rewrite Mode (Flash Memory Version)
Figure 1.29.3. Program flowchart
Program Command (40
Program operation starts when the command code “40
address and data to program are written in the 2nd bus cycle, program operation (data programming
and verification) will start. Make an address in the first bus cycle same as an address to program by
the second bus cycle.
Whether the write operation is completed can be confirmed by reading the status register or the RY/
_____
BY status flag. When the program starts, the read status register mode is accessed automatically and
the content of the status register is read into the data bus (D0 - D7). The status register bit 7 (SR7) is
set to 0 at the same time the write operation starts and is returned to 1 upon completion of the write
operation. In this case, the read status register mode remains active until the Read Array command
(FF
The RY/BY status flag is 0 during write operation and 1 when the write operation is completed as is
the status register bit 7.
At program end, program results can be checked by reading the status register.
Figure 1.29.3 shows an example of a program flowchart.
Each block of the flash memory can be write protected by using a lock bit. For details, refer to the
section where the data protect function is detailed.
Additional writes to the already programmed pages are prohibited.
Do a command to use in right after of program command as follows
Make an address in the first bus cycle same as an address to program by the second bus cycle of
program command.
16
) is written.
____
Write
Status register
completed
Write address
Write data
RY/BY=1?
SR4=0?
Write
Program
SR7=1?
16
Start
read
)
or
YES
YES
40
16
NO
NO
Program
(Set an address to even address in the user
ROM area when reading the status register)
error
16
” is written in the first bus cycle. Then, if the
SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER
M16C / 62N Group
Mitsubishi microcomputers
199

Related parts for M30624FGNGP#D5