MC9S12XDP512CAL Freescale, MC9S12XDP512CAL Datasheet - Page 425

MC9S12XDP512CAL

Manufacturer Part Number
MC9S12XDP512CAL
Description
Manufacturer
Freescale
Datasheet

Specifications of MC9S12XDP512CAL

Cpu Family
HCS12
Device Core Size
16b
Frequency (max)
40MHz
Interface Type
CAN/I2C/SCI/SPI
Total Internal Ram Size
32KB
# I/os (max)
91
Number Of Timers - General Purpose
12
Operating Supply Voltage (typ)
2.5/5V
Operating Supply Voltage (max)
2.75/5.5V
Operating Supply Voltage (min)
2.35/3.15V
On-chip Adc
2(16-chx10-bit)
Instruction Set Architecture
CISC
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
112
Package Type
LQFP
Program Memory Type
Flash
Program Memory Size
512KB
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC9S12XDP512CAL
Manufacturer:
FREESCALE
Quantity:
1 928
Part Number:
MC9S12XDP512CAL
Manufacturer:
FREESCALE
Quantity:
4
Part Number:
MC9S12XDP512CAL
Manufacturer:
FREESCA
Quantity:
2 246
Part Number:
MC9S12XDP512CAL
Manufacturer:
FREESCALE
Quantity:
4 576
Part Number:
MC9S12XDP512CAL
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC9S12XDP512CAL
Manufacturer:
FREESCALE
Quantity:
4 576
Write: Anytime when out of initialization mode; exceptions are read-only RXACT and SYNCH, RXFRM
(which is set by the module only), and INITRQ (which is also writable in initialization mode).
Freescale Semiconductor
RXFRM
CSWAI
SYNCH
RXACT
WUPE
Field
TIME
7
6
5
4
3
2
4
3
1
Received Frame Flag — This bit is read and clear only. It is set when a receiver has received a valid message
correctly, independently of the filter configuration. After it is set, it remains set until cleared by software or reset.
Clearing is done by writing a 1. Writing a 0 is ignored. This bit is not valid in loopback mode.
0 No valid message was received since last clearing this flag
1 A valid message was received since last clearing of this flag
Receiver Active Status — This read-only flag indicates the MSCAN is receiving a message. The flag is
controlled by the receiver front end. This bit is not valid in loopback mode.
0 MSCAN is transmitting or idle
1 MSCAN is receiving a message (including when arbitration is lost)
CAN Stops in Wait Mode — Enabling this bit allows for lower power consumption in wait mode by disabling all
the clocks at the CPU bus interface to the MSCAN module.
0 The module is not affected during wait mode
1 The module ceases to be clocked during wait mode
Synchronized Status — This read-only flag indicates whether the MSCAN is synchronized to the CAN bus and
able to participate in the communication process. It is set and cleared by the MSCAN.
0 MSCAN is not synchronized to the CAN bus
1 MSCAN is synchronized to the CAN bus
Timer Enable — This bit activates an internal 16-bit wide free running timer which is clocked by the bit clock rate.
If the timer is enabled, a 16-bit time stamp will be assigned to each transmitted/received message within the
active TX/RX buffer. Right after the EOF of a valid message on the CAN bus, the time stamp is written to the
highest bytes (0x000E, 0x000F) in the appropriate buffer (see
Storage”). The internal timer is reset (all bits set to 0) when disabled. This bit is held low in initialization mode.
0 Disable internal MSCAN timer
1 Enable internal MSCAN timer
Wake-Up Enable — This configuration bit allows the MSCAN to restart from sleep mode when traffic on CAN is
detected (see
the selected function to take effect.
0 Wake-up disabled — The MSCAN ignores traffic on CAN
1 Wake-up enabled — The MSCAN is able to restart
Section 10.4.5.4, “MSCAN Sleep
Table 10-1. CANCTL0 Register Field Descriptions
MC9S12XDP512 Data Sheet, Rev. 2.21
2
Chapter 10 Freescale’s Scalable Controller Area Network (S12MSCANV3)
Mode”). This bit must be configured before sleep mode entry for
Description
Section 10.3.3, “Programmer’s Model of Message
2
425