Start ADC Measurement SFR (ADCGO, 0xD8)
1-0
Bit
Location
7
6-3
2
1
0
RXPROG[1:0]
Bit
Addr.
0xDF
0xDE –
0xDB
0xDA
0xD9
0xD8
Bit
Name
PLL_FTL_ACK
Reserved
VSW_ADC_GO
TEMP_ADC_GO
BATT_ADC_GO
00
RXPROG [1:0]
0
0
1
Default
Value
0
0
0
0
0
0
1
1
Controls the function of the P1.0/RX pin.
Rev. PrD | Page 110 of 140
Description
Set this bit to clear the PLL fault bit, PLL_FLT in the PERIPH register. A PLL
fault is generated if a reset was caused because the PLL lost lock.
Reserved
Set this bit to initiate a supply voltage measurement. This bit will be
cleared when the measurement request is received by the ADC.
Set this bit to initiate a temperature measurement. This bit will be cleared
when the measurement request is received by the ADC.
Set this bit to initiate a battery measurement. This bit will be cleared when
the measurement request is received by the ADC.
Function
GPIO
RX with wakeup disabled
RX with wakeup enabled
Preliminary Technical Data