LM3S2965-IRN50-A1T ETC2 [List of Unclassifed Manufacturers], LM3S2965-IRN50-A1T Datasheet - Page 476

no-image

LM3S2965-IRN50-A1T

Manufacturer Part Number
LM3S2965-IRN50-A1T
Description
Microcontroller
Manufacturer
ETC2 [List of Unclassifed Manufacturers]
Datasheet
Pulse Width Modulator (PWM)
PWM Output Fault (PWMFAULT)
Base 0x4002.8000
Offset 0x010
Type R/W, reset 0x0000.0000
476
Reset
Reset
Type
Type
Bit/Field
31:6
5
4
3
2
1
0
RO
RO
31
15
0
0
Register 5: PWM Output Fault (PWMFAULT), offset 0x010
This register controls the behavior of the PWM outputs in the presence of fault conditions. Both the
fault input and debug events are considered fault conditions. On a fault condition, each PWM signal
can either be passed through unmodified or driven Low. For outputs that are configured for
pass-through, the debug event handling on the corresponding PWM generator also determines if
the PWM signal continues to be generated.
Fault condition control happens before the output inverter, so PWM signals driven Low on fault are
inverted if the channel is configured for inversion (therefore, the pin is driven High on a fault condition).
RO
RO
30
14
0
0
reserved
Name
Fault5
Fault4
Fault3
Fault2
Fault1
Fault0
RO
RO
29
13
0
0
RO
RO
28
12
0
0
RO
RO
Type
27
11
R/W
R/W
R/W
R/W
R/W
R/W
0
0
RO
reserved
RO
RO
26
10
0
0
Reset
0x00
0
0
0
0
0
0
RO
RO
25
0
9
0
Preliminary
Description
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
PWM5 Driven Low on Fault
When set, the PWM5 output signal is driven Low on a fault condition.
PWM4 Driven Low on Fault
When set, the PWM4 output signal is driven Low on a fault condition.
PWM3 Driven Low on Fault
When set, the PWM3 output signal is driven Low on a fault condition.
PWM2 Driven Low on Fault
When set, the PWM2 output signal is driven Low on a fault condition.
PWM1 Driven Low on Fault
When set, the PWM1 output signal is driven Low on a fault condition.
PWM0 Driven Low on Fault
When set, the PWM0 output signal is driven Low on a fault condition.
RO
RO
24
0
8
0
reserved
RO
RO
23
0
7
0
RO
RO
22
0
6
0
Fault5
R/W
RO
21
0
5
0
Fault4
R/W
RO
20
0
4
0
Fault3
R/W
RO
19
0
3
0
November 30, 2007
Fault2
R/W
RO
18
0
2
0
Fault1
R/W
RO
17
0
1
0
Fault0
R/W
RO
16
0
0
0

Related parts for LM3S2965-IRN50-A1T