z16f2811 ZiLOG Semiconductor, z16f2811 Datasheet - Page 256

no-image

z16f2811

Manufacturer Part Number
z16f2811
Description
High Performance Microcontrollers
Manufacturer
ZiLOG Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
z16f2811AL20AG
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z16f2811AL20EG
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z16f2811AL20SG
Manufacturer:
VISHAY
Quantity:
9 487
Part Number:
z16f2811AL20SG
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z16f2811AL20SG
Manufacturer:
ZILOG
Quantity:
20 000
Part Number:
z16f2811FI20AG
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z16f2811FI20EG
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z16f2811FI20SG
Manufacturer:
Zilog
Quantity:
155
ADC Control Register Definitions
PS022006-0207
ADC Interrupts
ADC0 Timer0 Capture
ADC Convert on Read
Reference Buffer, RBUF
Internal Voltage Reference Generator
The ADC generates an interrupt request when a conversion has been completed.
An interrupt request pending when the ADC is disabled is not automatically cleared.
The Timer0 count is captured for every ADC0 conversion. The information is used to
determine the zero crossing of back EMF in motor control applications. The capture of the
Timer0 count occurs when the programmed sample time is complete for every conversion
and stored in the ADC timer capture register (ADCTCAP).
The ADC is set up to automatically convert the next channel input after reading the results
of the current conversion. The conversions continue up to the channel listed in the
ADC0MAX register and then start over at the initial channel. The initial channel to con-
vert is written to the control register, ADC0CTL, prior to starting the convert on Read
process. Once started, the conversions continue to loop from the initial channel to Max
channel until the convert on Read bit,
data registers.
The reference buffer, RBUF, supplies the reference voltage for the ADC. When enabled,
the internal voltage reference generator supplies the ADC and the voltage is available on
the VREF pin. When RBUF is disabled, the reference voltage must be supplied externally
through the VREF pin. RBUF is controlled by the REFEN bit in the ADC0 control register.
The internal voltage reference generator provides the voltage to RBUF. The internal
reference voltage is 2 V.
The following sections describe the control registers for the ADC.
P R E L I M I N A R Y
CVTRD0
, is cleared or the data is not read from the
Product Specification
ZNEO
Analog Functions
Z16F Series
242

Related parts for z16f2811